{"id":3995,"date":"2026-10-14T17:51:30","date_gmt":"2026-10-14T16:51:30","guid":{"rendered":"https:\/\/wpcalc.com\/de\/ingenieurwesen\/leitungsschutzschalter-bemessung\/"},"modified":"2026-10-14T17:51:30","modified_gmt":"2026-10-14T16:51:30","slug":"leitungsschutzschalter-bemessung","status":"publish","type":"post","link":"https:\/\/wpcalc.com\/de\/ingenieurwesen\/leitungsschutzschalter-bemessung\/","title":{"rendered":"Leitungsschutzschalter richtig dimensionieren"},"content":{"rendered":"<section class=\"not-prose calculator-box\" aria-labelledby=\"calculator-title\"><div class=\"flex items-baseline sm:items-center justify-between gap-2 sm:gap-3\"><div class=\"flex flex-col sm:flex-row sm:items-center gap-2\"><span class=\"icon icon-calculator text-primary-700! text-base! dark:text-primary-300!\" aria-hidden=\"true\"><\/span><h2 id=\"calculator-title\" class=\"text-lg font-display font-bold\">Leitungsschutzschalter f\u00fcr eine bekannte Last dimensionieren<\/h2><\/div><div class=\"calcdash-favorite group\">\n  <button type=\"button\" class=\"favorite\" id=\"favorite\" data-favorite-id=\"3995\" data-favorite-title=\"Leitungsschutzschalter-Bemessung\" data-favorite-url=\"https:\/\/wpcalc.com\/de\/ingenieurwesen\/leitungsschutzschalter-bemessung\/\" data-favorite-excerpt=\"Finden Sie die richtige Gr\u00f6\u00dfe des Leitungsschutzschalters f\u00fcr jede Last. Geben Sie Leistung (oder Strom), Spannung, Phasenzahl und Leistungsfaktor ein \u2013 der Rechner wendet die 125-%-Regel f\u00fcr Dauerlasten an und rundet auf die n\u00e4chstgr\u00f6\u00dfere genormte Bemessungsgr\u00f6\u00dfe nach NEC auf.\" aria-label=\"Zu Favoriten hinzuf\u00fcgen\" data-favorite-icon=\"icon icon-electrical\">\n    <span class=\"icon icon-shape-star-empty\" aria-hidden=\"true\"><\/span>\n  <\/button>\n  <div class=\"calcdash-favorite__tip\" aria-hidden=\"true\">\n   <span class=\"favorite-tooltip\" id=\"favorite-tooltip\"><\/span>\n  <\/div>\n  <span class=\"sr-only\" role=\"status\" id=\"favorite-status\"><\/span>\n<\/div><\/div><form action=\"https:\/\/wpcalc.com\/de\/ingenieurwesen\/leitungsschutzschalter-bemessung\/\" method=\"POST\" class=\"calculator\" id=\"calculator-3995\" data-post=\"3995\"><fieldset class=\"fieldset-input is-2\"><legend class=\"sr-only\">Eingabefelder<\/legend><div class=\"field is-single\" id=\"input-1\"><label for=\"field-1\">Bekannte Gr\u00f6\u00dfe<\/label><div class=\"grid grid-cols-1\"><select id=\"field-1\" name=\"bekannte_gre\"><option value=\"power\" selected>Lastleistung (W \/ kW)<\/option><option value=\"current\">Laststrom (A)<\/option><\/select><svg class=\"pointer-events-none col-start-1 row-start-1 mr-2 size-5 self-center justify-self-end text-gray-500 sm:size-4\" viewBox=\"0 0 16 16\" fill=\"currentColor\" aria-hidden=\"true\" data-slot=\"icon\">\n              <path fill-rule=\"evenodd\" d=\"M4.22 6.22a.75.75 0 0 1 1.06 0L8 8.94l2.72-2.72a.75.75 0 1 1 1.06 1.06l-3.25 3.25a.75.75 0 0 1-1.06 0L4.22 7.28a.75.75 0 0 1 0-1.06Z\" clip-rule=\"evenodd\" \/>\n            <\/svg><\/div><\/div><div class=\"field has-term\" id=\"input-2\"><label for=\"field-2\">Lastleistung (P)<\/label><div class=\"term\">P<\/div>  <div class=\"absolute bottom-0 left-16 top-8 w-2 h-0.5 bg-blue-500\"><\/div><div class=\"field-group\"><input type=\"text\" name=\"lastleistung_p\" id=\"field-2\" aria-describedby=\"calc-info-2\" data-number inputmode=\"decimal\" autocomplete=\"off\" spellcheck=\"false\" min=\"0.1\" value=\"7.2\"\/><div class=\"grid grid-cols-1\"><select id=\"field-3\" name=\"einheit\" aria-label=\"Einheit\"><option value=\"W\">W<\/option><option value=\"kW\" selected>kW<\/option><\/select><svg class=\"pointer-events-none col-start-1 row-start-1 mr-2 size-5 self-center justify-self-end text-gray-500 sm:size-4\" viewBox=\"0 0 16 16\" fill=\"currentColor\" aria-hidden=\"true\" data-slot=\"icon\">\n              <path fill-rule=\"evenodd\" d=\"M4.22 6.22a.75.75 0 0 1 1.06 0L8 8.94l2.72-2.72a.75.75 0 1 1 1.06 1.06l-3.25 3.25a.75.75 0 0 1-1.06 0L4.22 7.28a.75.75 0 0 1 0-1.06Z\" clip-rule=\"evenodd\" \/>\n            <\/svg><\/div><\/div><small id=\"calc-info-2\">Gesamtanschlussleistung des Stromkreises<\/small><\/div><div class=\"field has-term\" id=\"input-3\"><label for=\"field-4\">Versorgungsspannung (V)<\/label><div class=\"term\">V<\/div>  <div class=\"absolute bottom-0 left-16 top-8 w-2 h-0.5 bg-blue-500\"><\/div><input type=\"text\" name=\"versorgungsspannung_v\" id=\"field-4\" aria-describedby=\"calc-unit-4 calc-info-4\" data-number inputmode=\"decimal\" autocomplete=\"off\" spellcheck=\"false\" min=\"1\" value=\"240\"\/><div class=\"unit\" id=\"calc-unit-4\">V<\/div><small id=\"calc-info-4\">Bei Drehstrom die verkettete Spannung (L\u2013L), bei Einphasigkeit die Spannung zwischen Au\u00dfenleiter und Neutralleiter (L\u2013N)<\/small><\/div><div class=\"field\" id=\"input-4\"><label for=\"field-5\">Netzform<\/label><div class=\"grid grid-cols-1\"><select id=\"field-5\" name=\"netzform\"><option value=\"single\" selected>Single-phase<\/option><option value=\"three\">Dreiphasig<\/option><\/select><svg class=\"pointer-events-none col-start-1 row-start-1 mr-2 size-5 self-center justify-self-end text-gray-500 sm:size-4\" viewBox=\"0 0 16 16\" fill=\"currentColor\" aria-hidden=\"true\" data-slot=\"icon\">\n              <path fill-rule=\"evenodd\" d=\"M4.22 6.22a.75.75 0 0 1 1.06 0L8 8.94l2.72-2.72a.75.75 0 1 1 1.06 1.06l-3.25 3.25a.75.75 0 0 1-1.06 0L4.22 7.28a.75.75 0 0 1 0-1.06Z\" clip-rule=\"evenodd\" \/>\n            <\/svg><\/div><\/div><div class=\"field has-term\" id=\"input-5\"><label for=\"field-6\">Leistungsfaktor (cos \u03c6)<\/label><div class=\"term\">cos \u03c6<\/div>  <div class=\"absolute bottom-0 left-16 top-8 w-2 h-0.5 bg-blue-500\"><\/div><input type=\"text\" name=\"leistungsfaktor_cos_\" id=\"field-6\" aria-describedby=\"calc-info-6\" data-number inputmode=\"decimal\" autocomplete=\"off\" spellcheck=\"false\" min=\"0.1\" max=\"1\" value=\"1\"\/><small id=\"calc-info-6\">Bei ohmschen Lasten 1,0 verwenden, sofern der tats\u00e4chliche Wert nicht bekannt ist<\/small><\/div><div class=\"field has-term\" id=\"input-6\" hidden><label for=\"field-7\">Laststrom (I)<\/label><div class=\"term\">I<\/div>  <div class=\"absolute bottom-0 left-16 top-8 w-2 h-0.5 bg-blue-500\"><\/div><input type=\"text\" name=\"laststrom_i\" id=\"field-7\" aria-describedby=\"calc-unit-7 calc-info-7\" data-number inputmode=\"decimal\" autocomplete=\"off\" spellcheck=\"false\" min=\"0.01\" value=\"30\"\/><div class=\"unit\" id=\"calc-unit-7\">A<\/div><small id=\"calc-info-7\">Stromaufnahme des Verbrauchers bei Volllast<\/small><\/div><div class=\"field is-checkbox is-single\" id=\"input-7\"><input type=\"checkbox\" id=\"field-8\" value=\"1\" checked=\"checked\"\/><label for=\"field-8\">Dauerlast \u2014 Auslegung mit 125 %<\/label><\/div><\/fieldset><div class=\"buttons\"><button type=\"submit\" data-text=\"Neu berechnen\" id=\"calculate-button\" data-post=\"3995\">Berechnen<\/button><button type=\"reset\">Zur\u00fccksetzen<\/button><\/div><div class=\"field is-checkbox hidden!\" id=\"field-auto-calc\"><input type=\"checkbox\" id=\"auto-calc\"><label for=\"auto-calc\">Automatisch berechnen<\/label><small>Wenn aktiviert, wird das Ergebnis automatisch aktualisiert, sobald Sie einen Wert \u00e4ndern.<\/small><\/div><div class=\"fieldset-result is-hidden\" aria-labelledby=\"result-title\" aria-live=\"polite\" role=\"region\"> <h3 class=\"result-title bg-gradient-to-r from-primary-50 to-gray-50 dark:from-primary-900 dark:to-gray-800\" id=\"result-title\"><span class=\"icon icon-s-pulse\" aria-hidden=\"true\"><\/span> Ergebnisse der Absicherungsberechnung<\/h3><div class=\"result-box\"><div class=\"field-result\" id=\"output-1\"><span class=\"field-title\"><span>Berechneter Laststrom<\/span><span class=\"result-term\">I<\/span><\/span><span class=\"field-value\" id=\"result-1\" data-unit=\"A\"><\/span><button type=\"button\" class=\"copy-result\" data-tooltip=\"Ergebnis kopieren\" aria-label=\"Ergebnis kopieren\"><span class=\"copy-icon icon icon-document-copy\" aria-hidden=\"true\"><\/span><\/button><\/div><div class=\"field-result\" id=\"output-2\"><span class=\"field-title\"><span>Minimaler Nennstrom des Leitungsschutzschalters<\/span><\/span><span class=\"field-value\" id=\"result-2\" data-unit=\"A\"><\/span><button type=\"button\" class=\"copy-result\" data-tooltip=\"Ergebnis kopieren\" aria-label=\"Ergebnis kopieren\"><span class=\"copy-icon icon icon-document-copy\" aria-hidden=\"true\"><\/span><\/button><\/div><div class=\"field-result is-column\" id=\"output-3\"><span class=\"field-title\"><span>Berechnungsdetails<\/span><\/span><span class=\"field-value\" id=\"result-3\"><\/span><button type=\"button\" class=\"copy-result\" data-tooltip=\"Ergebnis kopieren\" aria-label=\"Ergebnis kopieren\"><span class=\"copy-icon icon icon-document-copy\" aria-hidden=\"true\"><\/span><\/button><\/div><\/div><div class=\"result-actions\"><button type=\"button\" class=\"copy-link\"><svg viewBox=\"0 0 20 20\" fill=\"currentColor\" aria-hidden=\"true\"><path d=\"M12.232 4.232a2.5 2.5 0 0 1 3.536 3.536l-1.225 1.224a.75.75 0 0 0 1.061 1.06l1.224-1.224a4 4 0 0 0-5.656-5.656l-3 3a4 4 0 0 0 .225 5.865.75.75 0 0 0 .977-1.138 2.5 2.5 0 0 1-.142-3.667l3-3Z\"\/><path d=\"M11.603 7.963a.75.75 0 0 0-.977 1.138 2.5 2.5 0 0 1 .142 3.667l-3 3a2.5 2.5 0 0 1-3.536-3.536l1.225-1.224a.75.75 0 0 0-1.061-1.06l-1.224 1.224a4 4 0 1 0 5.656 5.656l3-3a4 4 0 0 0-.225-5.865Z\"\/><\/svg><span class=\"copy-link__text\">Link zu dieser Berechnung kopieren<\/span><\/button><span class=\"sr-only\" role=\"status\" id=\"copy-link-status\"><\/span><\/div><\/div><a href=\"#respond\" class=\"hidden transition-opacity duration-300 opacity-0 w-50 text-sm justify-center items-center gap-2 px-4 py-2 rounded bg-gray-200 text-gray-700 hover:bg-gray-300\" id=\"leave-comment\"><span class=\"icon icon-comments\" aria-hidden=\"true\"><\/span>Kommentar schreiben<\/a><\/form><\/section><section id=\"calc-reactions\" class=\"not-prose hidden my-12 bg-gradient-to-r from-primary-50 to-gray-50 border border-indigo-100 rounded-xl px-6 py-4 shadow-sm\" data-post=\"3995\" aria-live=\"polite\" aria-labelledby=\"calc-reactions-title\"><p id=\"calc-reactions-title\" class=\"text-sm text-gray-500 text-center mb-2\">Wie finden Sie dieses Ergebnis?<\/p><div role=\"group\" aria-labelledby=\"calc-reactions-title\" class=\"grid grid-cols-3 sm:flex sm:flex-row sm:justify-around gap-4 sm:items-center sm:flex-wrap\"><button type=\"button\" aria-pressed=\"false\" class=\"reaction-btn flex flex-col items-center gap-1 text-sm text-gray-700 hover:text-primary-600 cursor-pointer transition-transform hover:scale-105\" data-reaction=\"like\"><span class=\"reaction-count\" data-reaction-count=\"like\">0<\/span><span class=\"reaction text-3xl\" aria-hidden=\"true\">\ud83d\ude00 <\/span><span class=\"reaction-description font-medium\">Gef\u00e4llt mir <\/span><\/button><button type=\"button\" aria-pressed=\"false\" class=\"reaction-btn flex flex-col items-center gap-1 text-sm text-gray-700 hover:text-primary-600 cursor-pointer transition-transform hover:scale-105\" data-reaction=\"helpful\"><span class=\"reaction-count\" data-reaction-count=\"helpful\">0<\/span><span class=\"reaction text-3xl\" aria-hidden=\"true\">\ud83d\udca1 <\/span><span class=\"reaction-description font-medium\">Hilfreich <\/span><\/button><button type=\"button\" aria-pressed=\"false\" class=\"reaction-btn flex flex-col items-center gap-1 text-sm text-gray-700 hover:text-primary-600 cursor-pointer transition-transform hover:scale-105\" data-reaction=\"confused\"><span class=\"reaction-count\" data-reaction-count=\"confused\">0<\/span><span class=\"reaction text-3xl\" aria-hidden=\"true\">\ud83d\ude15 <\/span><span class=\"reaction-description font-medium\">Verwirrt <\/span><\/button><button type=\"button\" aria-pressed=\"false\" class=\"reaction-btn flex flex-col items-center gap-1 text-sm text-gray-700 hover:text-primary-600 cursor-pointer transition-transform hover:scale-105\" data-reaction=\"disappointed\"><span class=\"reaction-count\" data-reaction-count=\"disappointed\">0<\/span><span class=\"reaction text-3xl\" aria-hidden=\"true\">\ud83d\ude1e <\/span><span class=\"reaction-description font-medium\">Entt\u00e4uscht <\/span><\/button><button type=\"button\" aria-pressed=\"false\" class=\"reaction-btn flex flex-col items-center gap-1 text-sm text-gray-700 hover:text-primary-600 cursor-pointer transition-transform hover:scale-105\" data-reaction=\"inaccurate\"><span class=\"reaction-count\" data-reaction-count=\"inaccurate\">0<\/span><span class=\"reaction text-3xl\" aria-hidden=\"true\">\u274c <\/span><span class=\"reaction-description font-medium\">Ungenau <\/span><\/button><\/div><div id=\"reaction-message\" class=\"hidden mt-8 rounded-md border border-primary-100 bg-white\/50 backdrop-blur-sm px-4 py-2 text-sm text-center shadow-sm\"><\/div><\/section><div class=\"calcdash-ad not-prose calcdash-ad--calc_result calcdash-ad--in-article\"><ins class=\"adsbygoogle\" style=\"display:block\" data-ad-client=\"ca-pub-1721569815777345\" data-ad-slot=\"6317458308\" data-ad-layout=\"in-article\" data-ad-format=\"fluid\"><\/ins><script>(adsbygoogle = window.adsbygoogle || []).push({});<\/script><\/div>\n<style id=\"wpcoderpro-inline-1\">.formula-box {\r\n\tborder-bottom: none !important;\r\n}<\/style><section class=\"formula-box\" aria-labelledby=\"formula-title\">\r\n\t<div id=\"formula-title\" class=\"not-prose font-display mb-4\"><span class=\"icon icon-formula\" aria-hidden=\"true\"><\/span><h2>Leitungsschutzschalter-Bemessung<\/h2><\/div>\r\n\t<figure class=\"not-prose formula\">\r\n\t\t<figcaption class=\"formula-title\">Formel<\/figcaption>\r\n\t\t<div class=\"text-base text-gray-800\" id=\"formula\">\n\\[ I_{single} = \\frac{P}{V \\cdot PF} \\qquad I_{three} = \\frac{P}{\\sqrt{3} \\cdot V \\cdot PF} \\]\n\\[ I_{required} = 1.25 \\cdot I \\quad (\\text{Dauerlast}), \\qquad I_{required} = I \\quad (\\text{keine Dauerlast}) \\]\n<\/div>\r\n\t<\/figure>\r\n\t<\/p>\n<p><strong>Dabei bedeuten:<\/strong><\/p>\n<ul>\n<li>\\(P\\) \u2014 Leistung der Last in Watt (W)<\/li>\n<li>\\(V\\) \u2014 Versorgungsspannung in Volt (V): Au\u00dfenleiter-Neutralleiter-Spannung bei Einphasen-, verkettete Spannung bei Dreiphasen-Netzen<\/li>\n<li>\\(PF\\) \u2014 Leistungsfaktor der Last (0,1\u20131,0)<\/li>\n<li>\\(I\\) \u2014 Strom bei Volllast in Ampere (A)<\/li>\n<\/ul>\n<p>Die erste Formel rechnet die Leistung der Last in den Strom um, den der Schutzschalter f\u00fchren muss; die zweite setzt die Regel aus NEC 210.20(A) um, wonach eine Dauerlast (drei Stunden oder l\u00e4nger mit Maximlast betrieben) h\u00f6chstens 80 % der Bemessungsgr\u00f6\u00dfe des Schutzschalters ausmachen darf \u2013 was gleichbedeutend damit ist, den Schutzschalter mit 125 % des Laststroms zu bemessen. Die so ermittelte erforderliche Bemessungsgr\u00f6\u00dfe wird anschlie\u00dfend auf die n\u00e4chstgr\u00f6\u00dfere genormte Nenngr\u00f6\u00dfe nach NEC 240.6(A) aufgerundet: 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100, 110, 125, 150, 175, 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 1000, 1200, 1600, 2000 A.<\/p>\n<p>\r\n<\/section>\n<style id=\"wpcoderpro-inline-2\">.calculation-box {\r\n\tborder-bottom: none !important;\r\n}<\/style><section id=\"calculation\" class=\"calculation-box\" aria-labelledby=\"calculation-title\">\r\n\t<div id=\"calculation-title\" class=\"not-prose font-display\"><span class=\"icon icon-unordered-list\" aria-hidden=\"true\"><\/span><h2>Leitungsschutzschalter \u2013 Rechenbeispiel<\/h2><\/div>\r\n\r\n<\/p>\n<p><strong>Beispiel:<\/strong> eine einphasige Dauerlast von 7,2 kW an einer Versorgungsspannung von 240 V mit einem Leistungsfaktor von 1,0 (die Voreinstellungen des Rechners).<\/p>\n<p>\\[ I = \\frac{P}{V \\cdot PF} = \\frac{7200\\ \\. W}{240\\ \\. V \\cdot 1.0} = 30\\ \\. A \\]<\/p>\n<p>\\[ I_{required} = 1.25 \\cdot 30 = 37.5\\ \\. A \\]<\/p>\n<p>Die kleinste genormte Schutzschalter-Gr\u00f6\u00dfe, die nicht unter 37,5 A liegt, ist <strong>40 A<\/strong>.<\/p>\n<p><strong>Ergebnis:<\/strong> berechneter Laststrom = 30 A; minimale Nenngr\u00f6\u00dfe des Schutzschalters = 40 A (Scheinleistung \u2248 7,2 kVA).<\/p>\n<p>\n\r\n<\/section>\n<h2>So benutzen Sie den Leitungsschutzschalter-Rechner<\/h2>\n<ol>\n<li>W\u00e4hlen Sie die <strong>bekannte Gr\u00f6\u00dfe<\/strong> aus: \u201eLeistung der Last (W\/kW)\u201c, wenn Sie die Watt-Leistung des Ger\u00e4ts kennen, oder \u201eStrom der Last (A)\u201c, wenn das Typenschild den Volllaststrom direkt angibt.<\/li>\n<li>Haben Sie \u201eLeistung\u201c gew\u00e4hlt, geben Sie die <strong>Leistung der Last (P)<\/strong> ein und w\u00e4hlen die Einheit (W oder kW). Haben Sie \u201eStrom\u201c gew\u00e4hlt, \u00fcbernehmen Sie den <strong>Strom der Last (I)<\/strong> in Ampere vom Typenschild des Ger\u00e4ts.<\/li>\n<li>Geben Sie die <strong>Versorgungsspannung (V)<\/strong> ein: die Au\u00dfenleiter-Neutralleiter-Spannung bei Einphasen-Stromkreisen (z. B. 120 V oder 230 V), die verkettete Spannung bei Dreiphasen-Stromkreisen (z. B. 400 V oder 480 V).<\/li>\n<li>Stellen Sie die <strong>Phasenzahl<\/strong> auf Einphasig oder Dreiphasig.<\/li>\n<li>Geben Sie den <strong>Leistungsfaktor (PF)<\/strong> ein. Bei ohmschen Lasten wie Heizger\u00e4ten und Gl\u00fchlampen verwenden Sie 1,0; bei Motoren, Netzteilen und anderen induktiven Ger\u00e4ten den Typenschildwert, sofern bekannt (\u00fcblicherweise 0,8\u20130,9). Ein niedrigerer Leistungsfaktor bedeutet mehr Strom bei gleicher Leistung \u2013 ein vorsichtig niedrig angesetzter Wert ist also sicherer als 1,0.<\/li>\n<li>Lassen Sie das Kontrollk\u00e4stchen <strong>Dauerlast \u2013 mit 125 % bemessen<\/strong> aktiviert, wenn die Last drei Stunden oder l\u00e4nger mit ihrem maximalen Strom betrieben wird (Wallboxen, Warmwasserbereiter, Kompressoren). Deaktivieren Sie es nur bei kurzzeitigen oder intermittierenden Lasten.<\/li>\n<li>Lesen Sie die Ergebnisse ab: den <strong>berechneten Laststrom<\/strong>, die <strong>minimale Nenngr\u00f6\u00dfe des Schutzschalters<\/strong> aus der genormten NEC-Reihe sowie eine ausf\u00fchrliche Aufschl\u00fcsselung, die jeden Rechenschritt zeigt.<\/li>\n<\/ol>\n<h2>Was bedeutet Schutzschalter-Bemessung und warum ist sie so wichtig<\/h2>\n<p>Ein Leitungsschutzschalter sch\u00fctzt die Leitungen und Ger\u00e4te eines Stromkreises vor \u00dcberstrom. Flie\u00dft mehr Strom, als die Leiter sicher f\u00fchren k\u00f6nnen, \u00fcberhitzt die Isolierung \u2013 eine der h\u00e4ufigsten Ursachen f\u00fcr elektrische Br\u00e4nde. Der Schutzschalter muss daher klein genug sein, um auszul\u00f6sen, bevor die Leitung besch\u00e4digt wird, aber gro\u00df genug, um den normalen Laststrom dauerhaft ohne Fehlausl\u00f6sung zu f\u00fchren \u2013 einschlie\u00dflich der Anlaufstr\u00f6me beim Starten von Motoren und Netzteilen.<\/p>\n<p>Die Berechnung besteht aus zwei Schritten. Zun\u00e4chst wird der tats\u00e4chliche Laststrom ermittelt \u2013 entweder vom Typenschild oder durch Division der Leistung durch die Spannung (und bei Wechselstromlasten zus\u00e4tzlich durch den Leistungsfaktor). Anschlie\u00dfend wird der Bemessungsfaktor angewendet: Der National Electrical Code (NEC 210.20(A)) begrenzt eine Dauerlast auf 80 % der Bemessungsgr\u00f6\u00dfe des \u00dcberstromschutzes, sodass eine Dauerlast einen Schutzschalter von mindestens 125 % des Laststroms erfordert. Eine Dauerlast von 30 A braucht also einen Schutzschalter von mindestens 37,5 A, was auf einen genormten 40-A-Schalter aufgerundet wird.<\/p>\n<p>Das Endergebnis wird immer auf eine genormte Nenngr\u00f6\u00dfe aufgerundet, weil Schutzschalter nur in festen Gr\u00f6\u00dfen nach NEC 240.6(A) gefertigt werden \u2013 15, 20, 25, 30, 35, 40, 45, 50, 60 A und so weiter bis 2000 A. Der Rechner w\u00e4hlt stets die kleinste genormte Gr\u00f6\u00dfe, die den erforderlichen Wert erreicht oder \u00fcbersteigt, und nie weniger als 15 A \u2013 die kleinste genormte Schutzschalter-Gr\u00f6\u00dfe.<\/p>\n<p>Die Interpretation des Ergebnisses ist einfach: Die angezeigte Zahl ist die kleinstm\u00f6gliche zul\u00e4ssige Schutzschalter-Gr\u00f6\u00dfe. Ein gr\u00f6\u00dferer Wert ist nur zul\u00e4ssig, wenn die Strombelastbarkeit der Leiter und die Ger\u00e4teanschl\u00fcsse dies ebenfalls erlauben \u2013 Schutzschalter, Leitung und Steckdosen m\u00fcssen als aufeinander abgestimmtes System zusammenpassen.<\/p>\n<h2>Annahmen, Grenzen und Praxistipps<\/h2>\n<ul>\n<li><strong>Die Strombelastbarkeit der Leiter z\u00e4hlt.<\/strong> Dieser Rechner bemessen nur den Schutzschalter. Die Leitung muss eine Strombelastbarkeit von mindestens dem Laststrom haben und in den meisten F\u00e4llen der Schutzschalter-Gr\u00f6\u00dfe entsprechen oder \u00fcber ihr liegen. Pr\u00fcfen Sie mit dem <a href=\"https:\/\/wpcalc.com\/de\/ingenieurwesen\/awg-drahtstaerke\/\">Querschnitts-Rechner<\/a>, welcher Leiterquerschnitt zu Ihrem Strom und Ihrer Leitungsl\u00e4nge passt.<\/li>\n<li><strong>Spannungsfall kann eine dickere Leitung erzwingen.<\/strong> Bei langen Leitungen entscheidet oft nicht die Strombelastbarkeit, sondern der Spannungsfall \u00fcber den Querschnitt. Pr\u00fcfen Sie die Leitung mit dem <a href=\"https:\/\/wpcalc.com\/en\/engineering\/electrical-voltage-drop\/\">Spannungsfall-Rechner<\/a>.<\/li>\n<li><strong>Motor- und Klimalasten folgen Sonderregeln.<\/strong> F\u00fcr Motoren (NEC Article 430) und Klimager\u00e4te (Article 440) gelten eigene Bemessungstabellen auf Basis des Volllaststroms und der Angaben auf dem Typenschild, die gr\u00f6\u00dfere Schutzschalter erfordern k\u00f6nnen, als diese einfache Rechnung nahelegt.<\/li>\n<li><strong>Die \u201en\u00e4chstgr\u00f6\u00dfere Gr\u00f6\u00dfe\u201c-Regel ist begrenzt.<\/strong> NEC 240.4(B) erlaubt unter bestimmten Bedingungen den n\u00e4chstgr\u00f6\u00dferen genormten Schutzschalter f\u00fcr feste, nicht-kontinuierliche Lasten \u2013 aber nur, wenn die Strombelastbarkeit der Leiter mindestens dem Laststrom entspricht und die Vergr\u00f6\u00dferung nicht \u00fcber die n\u00e4chstgr\u00f6\u00dfere genormte Stufe hinausgeht. Auf Dauerlasten oder Stromkreise mit Steckdosen f\u00fcr ortsver\u00e4nderliche Verbraucher ist sie nie anwendbar.<\/li>\n<li><strong>Annahmen zum Leistungsfaktor.<\/strong> Wer bei einer induktiven Last PF = 1,0 ansetzt, untersch\u00e4tzt den Strom. Ist der Leistungsfaktor einer Motorlast auf dem Typenschild nicht angegeben, liefert der vorsichtige Ansatz 0,8 das sicherere Ergebnis. Ein schlechter Leistungsfaktor l\u00e4sst sich auch an der Quelle verbessern \u2013 siehe den <a href=\"https:\/\/wpcalc.com\/en\/engineering\/power-factor-correction\/\">Rechner zur Leistungsfaktor-Korrektur<\/a>.<\/li>\n<li><strong>Vorschriften unterscheiden sich je nach Land.<\/strong> Dieser Rechner folgt den NEC-Konventionen Nordamerikas. IEC-basierte Normen in anderen Regionen arbeiten mit \u00e4hnlichen Prinzipien, aber anderen genormten Gr\u00f6\u00dfen und Bemessungsfaktoren \u2013 gleichen Sie das Ergebnis immer mit Ihrer \u00f6rtlichen Elektroinstallationsnorm ab.<\/li>\n<li><strong>Sicherheit geht vor.<\/strong> Arbeiten am Stromkreisverteiler erfolgen an freiliegenden, unter Spannung stehenden Klemmen. Lassen Sie die Installation von einem Elektrofachmann ausf\u00fchren oder pr\u00fcfen und ersetzen Sie niemals einen Schutzschalter durch einen gr\u00f6\u00dferen, ohne vorher Leitung und Ger\u00e4te auf ihre Bemessungswerte zu kontrollieren.<\/li>\n<\/ul>\n<h2>Genormte Schutzschalter-Gr\u00f6\u00dfen (NEC 240.6(A))<\/h2>\n<table>\n<thead>\n<tr>\n<th>Strombereich<\/th>\n<th>Typische Anwendung<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>15\u201320 A<\/td>\n<td>Beleuchtung, allgemeine Steckdosenstromkreise<\/td>\n<\/tr>\n<tr>\n<td>30\u201350 A<\/td>\n<td>Warmwasserbereiter, W\u00e4schetrockner, Herde, EV-Laden<\/td>\n<\/tr>\n<tr>\n<td>60\u2013100 A<\/td>\n<td>Unterverteilungen, gro\u00dfe Klimaanlagen, schnelle Wallboxen<\/td>\n<\/tr>\n<tr>\n<td>125\u2013400 A<\/td>\n<td>Hausanschluss, Hauptverteilung<\/td>\n<\/tr>\n<tr>\n<td>400\u20132000 A<\/td>\n<td>Gewerbliche und industrielle Schaltanlagen<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>F\u00fcr die \u00fcbrige Kreisberechnung decken der <a href=\"https:\/\/wpcalc.com\/en\/engineering\/ohms-law\/\">Rechner zum Ohmschen Gesetz<\/a> und der <a href=\"https:\/\/wpcalc.com\/en\/engineering\/prospective-short-circuit-current\/\">Kurzschlussstrom-Rechner<\/a> die andere Seite der Auslegung ab: die Pr\u00fcfung, ob das Ausschaltverm\u00f6gen des Schutzschalters f\u00fcr den Fehlerstrom am Verteiler ausreicht.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Finden Sie die richtige Gr\u00f6\u00dfe des Leitungsschutzschalters f\u00fcr jede Last. Geben Sie Leistung (oder Strom), Spannung, Phasenzahl und Leistungsfaktor ein \u2013 der Rechner wendet die 125-%-Regel f\u00fcr Dauerlasten an und rundet auf die n\u00e4chstgr\u00f6\u00dfere genormte Bemessungsgr\u00f6\u00dfe nach NEC auf.<\/p>\n","protected":false},"author":3168,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[6],"tags":[35],"class_list":["post-3995","post","type-post","status-publish","format-standard","hentry","category-ingenieurwesen","tag-elektrotechnik"],"acf":[],"_links":{"self":[{"href":"https:\/\/wpcalc.com\/de\/wp-json\/wp\/v2\/posts\/3995","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wpcalc.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/wpcalc.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/wpcalc.com\/de\/wp-json\/wp\/v2\/users\/3168"}],"replies":[{"embeddable":true,"href":"https:\/\/wpcalc.com\/de\/wp-json\/wp\/v2\/comments?post=3995"}],"version-history":[{"count":0,"href":"https:\/\/wpcalc.com\/de\/wp-json\/wp\/v2\/posts\/3995\/revisions"}],"wp:attachment":[{"href":"https:\/\/wpcalc.com\/de\/wp-json\/wp\/v2\/media?parent=3995"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/wpcalc.com\/de\/wp-json\/wp\/v2\/categories?post=3995"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/wpcalc.com\/de\/wp-json\/wp\/v2\/tags?post=3995"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}