Manning Open Channel Flow
Calculate the velocity, discharge, flow area and hydraulic radius of water flowing in an open channel or part-full pipe using the Manning equation. Choose the channel shape and enter its dimensions, slope and roughness.
Estimate Velocity and Discharge with the Manning Equation
Manning Equation Formula
Where:
- \(v\) — mean flow velocity (m/s)
- \(Q\) — discharge, the volume of water passing per second (m³/s)
- \(n\) — Manning roughness coefficient (dimensionless)
- \(A\) — cross-sectional flow area (m²)
- \(R\) — hydraulic radius (m), equal to the flow area divided by the wetted perimeter \(P\)
- \(S\) — bed slope (dimensionless, m of fall per m of length)
- \(b\) — bottom width of the channel (m)
- \(y\) — water depth (m)
- \(z\) — side slope, horizontal run per unit vertical rise
The Manning equation is an empirical relationship that links the velocity of uniform open-channel flow to the geometry of the wetted cross-section, the roughness of the boundary and the slope of the channel. In US customary units the constant 1.486 replaces 1 so that velocities come out in ft/s; the imperial results shown by this calculator already account for that conversion.
Manning Flow – Calculation Example
Example: a rectangular concrete-lined drainage channel, 1 m wide (\(b = 1\) m), carries water 0.5 m deep (\(y = 0.5\) m). The bed falls 5 mm per metre (\(S = 0.005\)) and the lining is smooth concrete (\(n = 0.013\)).
\[ A = b\,y = 1 \times 0.5 = 0.5\ \text{m}^2 \qquad P = b + 2y = 1 + 1 = 2\ \text{m} \qquad R = \frac{A}{P} = \frac{0.5}{2} = 0.25\ \text{m} \]
\[ v = \frac{1}{n} R^{2/3} S^{1/2} = \frac{1}{0.013} \times 0.25^{2/3} \times 0.005^{1/2} = 76.92 \times 0.3969 \times 0.07071 \approx 2.16\ \text{m/s} \]
\[ Q = A\,v = 0.5 \times 2.16 \approx 1.08\ \text{m}^3/\text{s} \]
Result: flow area \(A \approx 0.5\ \text{m}^2\) (5.38 ft²), hydraulic radius \(R = 0.25\ \text{m}\), mean velocity \(v \approx 2.16\ \text{m/s}\) (7.08 ft/s), discharge \(Q \approx 1.08\ \text{m}^3/\text{s}\) (38.1 ft³/s).
How to use the calculator
- Select the Channel shape — Rectangular, Trapezoidal, Triangular (V-shaped) or Circular (part-full pipe). Only the dimensions relevant to that shape are shown.
- For rectangular and trapezoidal channels, enter the Bottom width (b) and pick its unit.
- For trapezoidal and triangular channels, enter the Side slope (z) — the horizontal run per unit of vertical rise (z = 2 means a 2H:1V bank).
- For a circular pipe, enter its Diameter (D); the pipe may flow partially full.
- Enter the Water depth (y) measured vertically from the bed (for a pipe it must not exceed the diameter).
- Enter the Bed slope (S) in m/m, percent, or inches per foot of length.
- Enter the Manning roughness (n) for the channel lining — 0.010–0.012 for smooth pipe, 0.013–0.015 for concrete, about 0.025 for earth and 0.035 for grassed channels.
The calculator returns the flow area, hydraulic radius (with the wetted perimeter), mean velocity and discharge, each in metric and imperial units.
What is Manning open channel flow?
Open channel flow is gravity-driven flow with a free water surface — rivers, irrigation ditches, storm drains, culverts and sewer pipes that are not running full. Unlike pressurized pipe flow, where the driving force is a pressure difference, the water here is pulled along by the slope of the channel, and energy is lost to friction against the bed and banks.
Published by Robert Manning in 1889, the Manning equation (also called the Gauckler–Manning formula) is the standard engineering tool for estimating uniform flow capacity. It balances two effects: the steeper the slope and the larger and more efficient the cross-section, the faster the water moves; and the rougher the boundary (larger \(n\)), the slower it moves. The key geometric quantity is the hydraulic radius \(R = A/P\) — flow area divided by wetted perimeter — which measures how much flow a section carries per unit of friction-producing boundary. Wide, shallow channels have small \(R\) and flow slowly; compact sections with \(R\) close to \(y\) are hydraulically efficient.
The discharge \(Q = A\,v\) is usually the design number: it tells you how much water the channel can pass at the given depth, or — working in reverse — whether a proposed channel can carry a required storm flow. Because \(v\) grows with \(R^{2/3}\), small increases in depth or width disproportionately increase capacity, while the sensitivity to \(n\) is linear, which is why choosing a realistic roughness value matters more than precise geometry in many designs.
If you also need to check whether the flow regime is turbulent or to size a pump moving the same water afterwards, see the Reynolds number and pump power calculators.
Assumptions, limitations and practical tips
- Steady, uniform flow: the Manning equation assumes depth and velocity do not change along the channel, so the water surface is parallel to the bed and the energy slope equals the bed slope. Near drops, weirs, junctions or sudden slope changes the flow is non-uniform and results will deviate.
- Part-full pipes: capacity peaks at roughly 93% of the diameter, not at full flow, because the wetted perimeter grows faster than the area as the pipe closes up. Sewers are therefore commonly designed to run at d/D ≤ 0.75 to leave an air gap and avoid pressurized surcharge.
- Roughness is not constant: \(n\) varies with surface finish, alignment, vegetation, debris and depth. A grassed channel that is clean at low flow can have a much higher effective \(n\) when weeds grow, so use a conservative value for design.
- Velocity limits: check the result against permissible values. Very high velocities (above about 2–3 m/s in earth channels) cause erosion, while very low velocities (below about 0.6–0.9 m/s) allow sediment to settle in storm and sewer systems.
- Compound sections: the formula shown covers single regular shapes. Flooded channels with a main channel and flat berms need to be split into sub-sections computed separately and summed.
- Unit consistency: the SI form of the equation (constant 1) requires metres and seconds; the imperial form uses the constant 1.486. The calculator converts your inputs automatically and displays both unit systems, so no manual conversion is needed.
Frequently Asked Questions
How do I find the water depth for a required discharge (normal depth)?
The Manning equation cannot be rearranged algebraically for depth, because the area and hydraulic radius both depend on it. The standard approach is trial and error: guess a depth, compute \(Q\) with the calculator, and adjust until the discharge matches your target. Start near half the channel depth and narrow in — three or four iterations usually get within a percent. Designing the channel invert elevation then means setting the bed so this normal depth is maintained along the reach.
What slope units do I enter, and how do I convert them?
Slope is a fall-to-length ratio and must be dimensionless before it enters the equation. 1% = 0.01 m/m, and a slope given as 1 in 100 also means 0.01. US drawings often use inches per foot: 1/8 in/ft equals about 0.0104 m/m. The calculator accepts m/m, percent and in/ft directly, so pick the unit matching your drawing rather than converting by hand — a slope entered as 0.5 when it should be 0.005 (percent vs m/m) is one of the most common and costly input mistakes.
How accurate is the Manning equation, and when should I not trust it?
For steady, uniform flow in a regular channel with a well-chosen \(n\), expect results within roughly 10–25% of measured values. Accuracy drops near controls such as weirs, drops, culvert inlets, junctions and slope changes, where the flow accelerates or backs up (gradually varied flow). Natural rivers with bends, pools and floodplains also need judgment — many engineers split compound sections and add a margin instead of trusting a single number.
What is the difference between hydraulic radius and hydraulic depth?
Hydraulic radius \(R = A/P\) uses the wetted perimeter — only the bed and banks in contact with water — and appears in the Manning equation. Hydraulic depth \(A/T\) (top width \(T\)) is a different quantity used to compute the Froude number and classify subcritical vs supercritical flow. For a very wide rectangular channel \(R\) approaches the depth \(y\), but in narrow or part-full circular sections they differ significantly, so never substitute one for the other.
Can I use the Manning equation for a pipe flowing full?
Not reliably. A full pipe has no free surface — the flow becomes pressurized and is driven by pressure head rather than bed slope, so you should switch to the Darcy–Weisbach or Hazen–Williams approach instead. Manning is acceptable up to about 75–80% depth in most sewer practice, where an air gap still exists and the flow remains open-channel. Note that a part-full circular pipe actually carries its maximum discharge at roughly \(y = 0.93D\), not when full.
How do I choose the Manning roughness coefficient n for my channel?
Published tables give typical ranges: glass or smooth PVC pipe 0.009–0.011, finished concrete 0.012–0.015, straight earth ditches 0.020–0.030, gravel beds 0.025–0.040, and grassed or weedy channels 0.035–0.15. Pick the value for the worst expected condition, not the as-built state — vegetation, sediment and poor alignment all raise effective roughness over time. Because \(v\) is inversely proportional to \(n\), a 30% underestimate of roughness means a 30% overestimate of capacity.
Is Manning the same as the Chezy formula?
Both describe uniform open-channel flow, but they differ. The Chezy equation \(v = C\sqrt{RS}\) uses a coefficient \(C\) that depends on both roughness and hydraulic radius, while Manning fixed an empirical power law \(v = (1/n)R^{2/3}S^{1/2}\) that works well for most natural and engineered channels. The two are related through \(C = R^{1/6}/n\). Manning has largely replaced Chezy in everyday practice because \(n\) values are well documented and vary less with channel size.