Pump Power

Updated:

Calculate the hydraulic and shaft power needed to pump a fluid. Enter flow rate, head or pressure rise, fluid density and pump efficiency to get results in kW and hp.

Calculate the Power Required to Pump a Fluid

Input Fields
Q
H
As head (m, ft) or as pressure rise (kPa, bar, psi)
ρ
η
%
If enabled, the result will update automatically when you change any value.

Pump Power Formula

Formula
\[ P_h = \rho \, g \, Q \, H \] \[ P = \frac{P_h}{\eta} = \frac{\rho \, g \, Q \, H}{\eta} \]

Where:

  • \(P_h\) — hydraulic power delivered to the fluid (W)
  • \(P\) — required input (shaft) power of the pump (W)
  • \(\rho\) — fluid density (kg/m³)
  • \(g\) — gravitational acceleration, \(9.81 \, \text{m/s}^2\)
  • \(Q\) — volumetric flow rate (m³/s)
  • \(H\) — pump head (m)
  • \(\eta\) — pump efficiency (as a decimal, e.g. 0.70 for 70 %)

The first equation gives the useful hydraulic power transferred to the fluid; dividing by the efficiency accounts for losses inside the pump and yields the power the motor must supply at the shaft.

If your data is given as a pressure rise \(\Delta p\) instead of a head, use the equivalent form \(P_h = Q \, \Delta p\), since \(\Delta p = \rho g H\).

Pump Power – Calculation Example

Example: a pump lifts water at 50 m³/h against a head of 20 m. The fluid is water with a density of 1000 kg/m³ and the pump efficiency is 70 %.

\[ Q = \frac{50}{3600} = 0.01389 \, \text{m}^3/\text{s} \]

\[ P_h = 1000 \times 9.81 \times 0.01389 \times 20 = 2725 \, \text{W} \approx 2.725 \, \text{kW} \]

\[ P = \frac{2725}{0.70} = 3893 \, \text{W} \approx 3.893 \, \text{kW} \]

\[ P = \frac{3893}{745.7} \approx 5.22 \, \text{hp} \]

Result: the hydraulic power is 2.725 kW, and the pump requires about 3.893 kW (5.22 hp) of shaft input power.

How to use the calculator

  1. Enter the Flow rate (Q) and select its unit: m³/h, L/s, L/min, m³/s or US gpm.
  2. Enter the Pressure rise / head (H). You can enter it as head in metres or feet of fluid, or directly as a pressure rise in kPa, bar or psi.
  3. Enter the Fluid density (ρ) in kg/m³ or lb/ft³. For cold water use 1000 kg/m³; for other fluids use the density at the operating temperature.
  4. Enter the Pump efficiency (η) as a percentage between 1 and 100. Typical centrifugal pumps run at 60–85 %; enter 100 % only if you want the ideal (loss-free) hydraulic power.
  5. Read the results: Hydraulic power, Required input (shaft) power in kW, and the same input power expressed in horsepower.

What is pump power?

Pump power is the rate at which energy must be supplied to move a fluid from one point to another. The hydraulic power is the useful part: the energy per second actually transferred to the fluid to raise its pressure and elevation. The shaft power is what the motor must deliver to the pump shaft; because real pumps lose energy to friction, leakage and turbulence, the shaft power is always higher than the hydraulic power.

The key quantity is the head — the total height equivalent (in metres or feet of fluid) that the pump must overcome. It includes static elevation difference, pressure difference between inlet and outlet, and friction losses in pipes, valves and fittings. If you already know the pressure rise the pump must produce, you can enter it directly in kPa, bar or psi and the calculator converts it using \( \Delta p = \rho g H \).

Interpreting the result is straightforward: the hydraulic power tells you how much work the fluid receives, while the shaft power tells you what size of motor or engine you need. When selecting a motor, it is wise to choose one with a rating slightly above the calculated shaft power to cover variations in operating conditions and to avoid running the motor at its limit.

Density matters more than many users expect. Pumping a dense fluid such as brine or slurry at the same flow rate and head requires proportionally more power than pumping water, because the head is expressed in metres of that fluid — the pressure and power scale linearly with \(\rho\).

Assumptions and limitations

  • The calculator assumes steady-state operation with a constant flow rate and head; it does not model start-up transients or cavitation.
  • The efficiency entered is the pump (hydraulic) efficiency only. Motor and drive losses are not included; if you need the electrical input power, also account for the motor efficiency (typically 90–97 %).
  • The head you enter should be the total dynamic head, including pipe friction and fittings — not just the static lift. Underestimating friction losses leads to an undersized pump.
  • When entering a pressure rise in kPa, bar or psi, the density value does not affect the result (it is already contained in the pressure), but it is still used for unit-consistency checks when head units are selected.
  • Gravitational acceleration is fixed at \(9.81 \, \text{m/s}^2\), which is accurate for virtually all locations on Earth.
  • The result applies to the rated duty point. A pump's actual power draw varies along its performance curve, so check the manufacturer's curve at your specific flow and head.

Practical tips

For quick estimates with cold water, you can use the shortcut \( P_h \approx \frac{Q \, H}{367} \) kW, with \(Q\) in m³/h and \(H\) in metres. If you are also sizing the electrical side of the installation — cables, voltage drop or power factor correction for the pump motor — the Voltage Drop and Power Factor Correction calculators may be useful companions, and the Wire Gauge calculator helps you select a suitable supply conductor.

Frequently Asked Questions

How do I calculate pump power by hand?

Multiply the fluid's density, gravity, flow rate and head: \(P_h = \rho g Q H\). Convert the flow rate to m³/s first (divide m³/h by 3600), keep the head in metres, and the result is hydraulic power in watts. Then divide by the pump efficiency as a decimal (e.g. 0.7) to get the shaft power the motor must supply. For a quick water-only estimate, \(P_h \approx \frac{Q H}{367}\) kW with \(Q\) in m³/h.

What is a good pump efficiency value to use?

Most well-sized centrifugal pumps operate between 60 % and 85 % at their best efficiency point (BEP). Small pumps (< 5 kW) often sit at 50–70 %, while large, well-designed ones can exceed 85 %. Positive-displacement pumps typically run 70–90 %. If you don't know the exact value yet, use 70 % for an initial estimate and refine it once you've selected a specific pump — the real value depends on where you operate on its performance curve.

How do I convert between head and pressure rise?

They are linked by \(\Delta p = \rho g H\). For cold water, 1 bar ≈ 10.2 m of head, and 1 psi ≈ 2.31 ft of head. To go from pressure to head, divide the pressure by \(\rho g\). Note that the conversion depends on the fluid: 1 bar of pressure equals 10.2 m of water head but only about 8.8 m of diesel head, because diesel is less dense. If you enter pressure directly (kPa, bar, psi), the density is already included in your value.

Why is my calculated shaft power lower than my motor's rating — is that wrong?

It's normal and usually correct. Motor nameplate ratings are often chosen 10–25 % above the calculated shaft power to handle start-up surges, variations in duty point and service factors. Also, the calculator only covers pump efficiency; if you want the electrical power drawn from the grid, divide the shaft power by the motor efficiency as well (typically 90–97 %). A motor running continuously near 100 % load will also run hotter and wear faster.

Does the head include pipe friction, or just the vertical lift?

It must include both — what you need is the total dynamic head (TDH): static elevation difference plus pressure difference between source and destination plus friction losses through pipes, valves and fittings. A common mistake is entering only the vertical lift, which can underestimate the required power by 30 % or more on long or narrow pipe runs. Estimate friction losses from pipe sizing charts or the Hazen–Williams/Darcy–Weisbach equations before using this calculator.

How does fluid viscosity or density affect the pump power?

Density scales the power directly: pumping a brine at 1100 kg/m³ instead of water at 1000 kg/m³ requires about 10 % more power at the same flow and head. Viscosity is different — this calculator assumes a fluid close to water. Highly viscous fluids (oils, slurries) reduce pump efficiency significantly and shift the performance curve, so you should derate both efficiency and flow using manufacturer correction factors (e.g. ANSI/HI 9.6.7 viscosity correction charts) for accurate results.

What's the difference between hydraulic power, shaft power and electrical power?

Hydraulic power is the useful energy delivered to the fluid; shaft power is what the motor delivers to the pump shaft (hydraulic power ÷ pump efficiency); electrical power is what the motor draws from the supply (shaft power ÷ motor efficiency). For example, 2.7 kW of hydraulic power at 70 % pump efficiency and 95 % motor efficiency needs about 4.1 kW of electrical input. Each step accounts for different losses: internal pump losses, then motor and drive losses.