{"id":66969,"date":"2026-10-13T10:43:18","date_gmt":"2026-10-13T07:43:18","guid":{"rendered":"https:\/\/wpcalc.com\/en\/?p=66969"},"modified":"2026-10-13T10:43:18","modified_gmt":"2026-10-13T07:43:18","slug":"magnetic-flux-through-a-loop-calculator","status":"publish","type":"post","link":"https:\/\/wpcalc.com\/en\/physics\/magnetic-flux-through-a-loop-calculator\/","title":{"rendered":"Magnetic Flux Through a Loop Calculator"},"content":{"rendered":"<section class=\"not-prose calculator-box\" aria-labelledby=\"calculator-title\"><div class=\"flex items-baseline sm:items-center justify-between gap-2 sm:gap-3\"><div class=\"flex flex-col sm:flex-row sm:items-center gap-2\"><span class=\"icon icon-calculator text-primary-700! text-base! dark:text-primary-300!\" aria-hidden=\"true\"><\/span><h2 id=\"calculator-title\" class=\"text-lg font-display font-bold\">Find the Magnetic Flux Through a Loop<\/h2><\/div><div class=\"calcdash-favorite group\">\n  <button type=\"button\" class=\"favorite\" id=\"favorite\" data-favorite-id=\"66969\" data-favorite-title=\"Magnetic Flux Through a Loop\" data-favorite-url=\"https:\/\/wpcalc.com\/en\/physics\/magnetic-flux-through-a-loop-calculator\/\" data-favorite-excerpt=\"Calculate the magnetic flux through a loop from field strength (B), loop area (A) and the angle to the surface normal. Enter values in any unit and get flux in webers, millawebers and microwebers.\" aria-label=\"Add to Favorites\" data-favorite-icon=\"icon icon-physic\">\n    <span class=\"icon icon-shape-star-empty\" aria-hidden=\"true\"><\/span>\n  <\/button>\n  <div class=\"calcdash-favorite__tip\" aria-hidden=\"true\">\n   <span class=\"favorite-tooltip\" id=\"favorite-tooltip\"><\/span>\n  <\/div>\n  <span class=\"sr-only\" role=\"status\" id=\"favorite-status\"><\/span>\n<\/div><\/div><form action=\"https:\/\/wpcalc.com\/en\/physics\/magnetic-flux-through-a-loop-calculator\/\" method=\"POST\" class=\"calculator\" id=\"calculator-66969\" data-post=\"66969\"><fieldset class=\"fieldset-input is-2\"><legend class=\"sr-only\">Input Fields<\/legend><div class=\"field has-term\" id=\"input-1\"><label for=\"field-1\">Magnetic Flux Density (B)<\/label><div class=\"term\">B<\/div>  <div class=\"absolute bottom-0 left-16 top-8 w-2 h-0.5 bg-blue-500\"><\/div><div class=\"field-group\"><input type=\"text\" name=\"magnetic_flux_density_b\" id=\"field-1\" aria-describedby=\"calc-info-1\" data-number inputmode=\"decimal\" autocomplete=\"off\" spellcheck=\"false\" placeholder=\"e.g. 5\" min=\"0\" value=\"5\"\/><div class=\"grid grid-cols-1\"><select id=\"field-2\" name=\"flux_density_unit\" aria-label=\"Flux density unit\"><option value=\"ut\">\u00b5T<\/option><option value=\"mt\" selected>mT<\/option><option value=\"t\">T<\/option><option value=\"g\">G<\/option><\/select><svg class=\"pointer-events-none col-start-1 row-start-1 mr-2 size-5 self-center justify-self-end text-gray-500 sm:size-4\" viewBox=\"0 0 16 16\" fill=\"currentColor\" aria-hidden=\"true\" data-slot=\"icon\">\n              <path fill-rule=\"evenodd\" d=\"M4.22 6.22a.75.75 0 0 1 1.06 0L8 8.94l2.72-2.72a.75.75 0 1 1 1.06 1.06l-3.25 3.25a.75.75 0 0 1-1.06 0L4.22 7.28a.75.75 0 0 1 0-1.06Z\" clip-rule=\"evenodd\" \/>\n            <\/svg><\/div><\/div><small id=\"calc-info-1\">Strength of the uniform magnetic field<\/small><\/div><div class=\"field has-term\" id=\"input-2\"><label for=\"field-3\">Loop Area (A)<\/label><div class=\"term\">A<\/div>  <div class=\"absolute bottom-0 left-16 top-8 w-2 h-0.5 bg-blue-500\"><\/div><div class=\"field-group\"><input type=\"text\" name=\"loop_area_a\" id=\"field-3\" aria-describedby=\"calc-info-3\" data-number inputmode=\"decimal\" autocomplete=\"off\" spellcheck=\"false\" placeholder=\"e.g. 200\" min=\"0\" value=\"200\"\/><div class=\"grid grid-cols-1\"><select id=\"field-4\" name=\"area_unit\" aria-label=\"Area unit\"><option value=\"mm2\">mm\u00b2<\/option><option value=\"cm2\" selected>cm\u00b2<\/option><option value=\"m2\">m\u00b2<\/option><option value=\"in2\">in\u00b2<\/option><option value=\"ft2\">ft\u00b2<\/option><\/select><svg class=\"pointer-events-none col-start-1 row-start-1 mr-2 size-5 self-center justify-self-end text-gray-500 sm:size-4\" viewBox=\"0 0 16 16\" fill=\"currentColor\" aria-hidden=\"true\" data-slot=\"icon\">\n              <path fill-rule=\"evenodd\" d=\"M4.22 6.22a.75.75 0 0 1 1.06 0L8 8.94l2.72-2.72a.75.75 0 1 1 1.06 1.06l-3.25 3.25a.75.75 0 0 1-1.06 0L4.22 7.28a.75.75 0 0 1 0-1.06Z\" clip-rule=\"evenodd\" \/>\n            <\/svg><\/div><\/div><small id=\"calc-info-3\">Area enclosed by the loop<\/small><\/div><div class=\"field is-single has-term\" id=\"input-3\"><label for=\"field-5\">Angle to Surface Normal (\u03b8)<\/label><div class=\"term\">\u03b8<\/div>  <div class=\"absolute bottom-0 left-16 top-8 w-2 h-0.5 bg-blue-500\"><\/div><input type=\"text\" name=\"angle_to_surface_normal_\" id=\"field-5\" aria-describedby=\"calc-unit-5 calc-info-5\" data-number inputmode=\"decimal\" autocomplete=\"off\" spellcheck=\"false\" placeholder=\"e.g. 30\" min=\"0\" max=\"180\" value=\"30\"\/><div class=\"unit\" id=\"calc-unit-5\">\u00b0<\/div><small id=\"calc-info-5\">Angle between the magnetic field and the normal (perpendicular) to the loop&#039;s surface<\/small><\/div><\/fieldset><div class=\"buttons\"><button type=\"submit\" data-text=\"Re-Calculate\" id=\"calculate-button\" data-post=\"66969\">Calculate<\/button><button type=\"reset\">Reset<\/button><\/div><div class=\"field is-checkbox hidden!\" id=\"field-auto-calc\"><input type=\"checkbox\" id=\"auto-calc\"><label for=\"auto-calc\">Calculate automatically<\/label><small>If enabled, the result will update automatically when you change any value.<\/small><\/div><div class=\"fieldset-result is-hidden\" aria-labelledby=\"result-title\" aria-live=\"polite\" role=\"region\"> <h3 class=\"result-title bg-gradient-to-r from-primary-50 to-gray-50 dark:from-primary-900 dark:to-gray-800\" id=\"result-title\"><span class=\"icon icon-s-pulse\" aria-hidden=\"true\"><\/span> Magnetic Flux Results<\/h3><div class=\"result-box\"><div class=\"field-result\" id=\"output-1\"><span class=\"field-title\"><span>Magnetic Flux<\/span><span class=\"result-term\">\u03a6<\/span><\/span><span class=\"field-value\" id=\"result-1\" data-unit=\"Wb\"><\/span><button type=\"button\" class=\"copy-result\" data-tooltip=\"Copy Result\" aria-label=\"Copy Result\"><span class=\"copy-icon icon icon-document-copy\" aria-hidden=\"true\"><\/span><\/button><\/div><div class=\"field-result\" id=\"output-2\"><span class=\"field-title\"><span>In Millawebers<\/span><span class=\"result-term\">\u03a6<\/span><\/span><span class=\"field-value\" id=\"result-2\" data-unit=\"mWb\"><\/span><button type=\"button\" class=\"copy-result\" data-tooltip=\"Copy Result\" aria-label=\"Copy Result\"><span class=\"copy-icon icon icon-document-copy\" aria-hidden=\"true\"><\/span><\/button><\/div><div class=\"field-result\" id=\"output-3\"><span class=\"field-title\"><span>In Microwebers<\/span><span class=\"result-term\">\u03a6<\/span><\/span><span class=\"field-value\" id=\"result-3\" data-unit=\"\u00b5Wb\"><\/span><button type=\"button\" class=\"copy-result\" data-tooltip=\"Copy Result\" aria-label=\"Copy Result\"><span class=\"copy-icon icon icon-document-copy\" aria-hidden=\"true\"><\/span><\/button><\/div><div class=\"field-result is-column\" id=\"output-4\"><span class=\"field-title\"><span>Calculation Details<\/span><\/span><span class=\"field-value\" id=\"result-4\"><\/span><button type=\"button\" class=\"copy-result\" data-tooltip=\"Copy Result\" aria-label=\"Copy Result\"><span class=\"copy-icon icon icon-document-copy\" aria-hidden=\"true\"><\/span><\/button><\/div><\/div><div class=\"result-actions\"><button type=\"button\" class=\"copy-link\"><svg viewBox=\"0 0 20 20\" fill=\"currentColor\" aria-hidden=\"true\"><path d=\"M12.232 4.232a2.5 2.5 0 0 1 3.536 3.536l-1.225 1.224a.75.75 0 0 0 1.061 1.06l1.224-1.224a4 4 0 0 0-5.656-5.656l-3 3a4 4 0 0 0 .225 5.865.75.75 0 0 0 .977-1.138 2.5 2.5 0 0 1-.142-3.667l3-3Z\"\/><path d=\"M11.603 7.963a.75.75 0 0 0-.977 1.138 2.5 2.5 0 0 1 .142 3.667l-3 3a2.5 2.5 0 0 1-3.536-3.536l1.225-1.224a.75.75 0 0 0-1.061-1.06l-1.224 1.224a4 4 0 1 0 5.656 5.656l3-3a4 4 0 0 0-.225-5.865Z\"\/><\/svg><span class=\"copy-link__text\">Copy link to this calculation<\/span><\/button><span class=\"sr-only\" role=\"status\" id=\"copy-link-status\"><\/span><\/div><\/div><a href=\"#respond\" class=\"hidden transition-opacity duration-300 opacity-0 w-50 text-sm justify-center items-center gap-2 px-4 py-2 rounded bg-gray-200 text-gray-700 hover:bg-gray-300\" id=\"leave-comment\"><span class=\"icon icon-comments\" aria-hidden=\"true\"><\/span>Leave a Comment<\/a><\/form><\/section><section id=\"calc-reactions\" class=\"not-prose hidden my-12 bg-gradient-to-r from-primary-50 to-gray-50 border border-indigo-100 rounded-xl px-6 py-4 shadow-sm\" data-post=\"66969\" aria-live=\"polite\" aria-labelledby=\"calc-reactions-title\"><p id=\"calc-reactions-title\" class=\"text-sm text-gray-500 text-center mb-2\">How did this result make you feel?<\/p><div role=\"group\" aria-labelledby=\"calc-reactions-title\" class=\"grid grid-cols-3 sm:flex sm:flex-row sm:justify-around gap-4 sm:items-center sm:flex-wrap\"><button type=\"button\" aria-pressed=\"false\" class=\"reaction-btn flex flex-col items-center gap-1 text-sm text-gray-700 hover:text-primary-600 cursor-pointer transition-transform hover:scale-105\" data-reaction=\"like\"><span class=\"reaction-count\" data-reaction-count=\"like\">0<\/span><span class=\"reaction text-3xl\" aria-hidden=\"true\">\ud83d\ude00 <\/span><span class=\"reaction-description font-medium\">Like <\/span><\/button><button type=\"button\" aria-pressed=\"false\" class=\"reaction-btn flex flex-col items-center gap-1 text-sm text-gray-700 hover:text-primary-600 cursor-pointer transition-transform hover:scale-105\" data-reaction=\"helpful\"><span class=\"reaction-count\" data-reaction-count=\"helpful\">0<\/span><span class=\"reaction text-3xl\" aria-hidden=\"true\">\ud83d\udca1 <\/span><span class=\"reaction-description font-medium\">Helpful <\/span><\/button><button type=\"button\" aria-pressed=\"false\" class=\"reaction-btn flex flex-col items-center gap-1 text-sm text-gray-700 hover:text-primary-600 cursor-pointer transition-transform hover:scale-105\" data-reaction=\"confused\"><span class=\"reaction-count\" data-reaction-count=\"confused\">0<\/span><span class=\"reaction text-3xl\" aria-hidden=\"true\">\ud83d\ude15 <\/span><span class=\"reaction-description font-medium\">Confused <\/span><\/button><button type=\"button\" aria-pressed=\"false\" class=\"reaction-btn flex flex-col items-center gap-1 text-sm text-gray-700 hover:text-primary-600 cursor-pointer transition-transform hover:scale-105\" data-reaction=\"disappointed\"><span class=\"reaction-count\" data-reaction-count=\"disappointed\">0<\/span><span class=\"reaction text-3xl\" aria-hidden=\"true\">\ud83d\ude1e <\/span><span class=\"reaction-description font-medium\">Disappointed <\/span><\/button><button type=\"button\" aria-pressed=\"false\" class=\"reaction-btn flex flex-col items-center gap-1 text-sm text-gray-700 hover:text-primary-600 cursor-pointer transition-transform hover:scale-105\" data-reaction=\"inaccurate\"><span class=\"reaction-count\" data-reaction-count=\"inaccurate\">0<\/span><span class=\"reaction text-3xl\" aria-hidden=\"true\">\u274c <\/span><span class=\"reaction-description font-medium\">Inaccurate <\/span><\/button><\/div><div id=\"reaction-message\" class=\"hidden mt-8 rounded-md border border-primary-100 bg-white\/50 backdrop-blur-sm px-4 py-2 text-sm text-center shadow-sm\"><\/div><\/section><div class=\"calcdash-ad not-prose calcdash-ad--calc_result calcdash-ad--in-article\"><ins class=\"adsbygoogle\" style=\"display:block\" data-ad-client=\"ca-pub-1721569815777345\" data-ad-slot=\"6317458308\" data-ad-layout=\"in-article\" data-ad-format=\"fluid\"><\/ins><script>(adsbygoogle = window.adsbygoogle || []).push({});<\/script><\/div>\n<style id=\"wpcoderpro-inline-1\">.formula-box {\r\n\tborder-bottom: none !important;\r\n}<\/style><section class=\"formula-box\" aria-labelledby=\"formula-title\">\r\n\t<div id=\"formula-title\" class=\"not-prose font-display mb-4\"><span class=\"icon icon-formula\" aria-hidden=\"true\"><\/span><h2>Magnetic Flux Through a Loop Formula<\/h2><\/div>\r\n\t<figure class=\"not-prose formula\">\r\n\t\t<figcaption class=\"formula-title\">Formula<\/figcaption>\r\n\t\t<div class=\"text-base text-gray-800\" id=\"formula\">\n\\[ \\Phi = B \\cdot A \\cdot \\cos(\\theta) \\]\n<\/div>\r\n\t<\/figure>\r\n\t<\/p>\n<p><strong>Where:<\/strong><\/p>\n<ul>\n<li>\\(\\Phi\\) \u2014 magnetic flux (webers, Wb)<\/li>\n<li>\\(B\\) \u2014 magnetic flux density, i.e. the strength of the uniform field (teslas, T)<\/li>\n<li>\\(A\\) \u2014 area enclosed by the loop (m\u00b2)<\/li>\n<li>\\(\\theta\\) \u2014 angle between the magnetic field and the <em>normal<\/em> (perpendicular) to the loop's surface (degrees or radians)<\/li>\n<\/ul>\n<p>The formula gives the total magnetic field passing through a flat loop. Only the component of the field perpendicular to the loop's surface contributes, which is why the cosine factor appears. The equivalent unit relation is \\(1\\ \\text{Wb} = 1\\ \\text{T}\\cdot\\text{m}^2 = 1\\ \\text{V}\\cdot\\text{s}\\).<\/p>\n<p>\r\n<\/section>\n<style id=\"wpcoderpro-inline-459\">.calculation-box {\r\n\tborder-bottom: none !important;\r\n}<\/style><section id=\"calculation\" class=\"calculation-box\" aria-labelledby=\"calculation-title\">\r\n\t<div id=\"calculation-title\" class=\"not-prose font-display\"><span class=\"icon icon-unordered-list\" aria-hidden=\"true\"><\/span><h2>Magnetic Flux Through a Loop \u2013 Calculation Example<\/h2><\/div>\r\n\r\n<\/p>\n<p><strong>Example:<\/strong> a flat circular loop with an area of 200 cm\u00b2 sits in a uniform 5 mT magnetic field. The field makes a 30\u00b0 angle with the normal to the loop's surface.<\/p>\n<p>Convert to SI units: \\(B = 5\\ \\text{mT} = 0.005\\ \\text{T}\\) and \\(A = 200\\ \\text{cm}^2 = 0.02\\ \\text{m}^2\\).<\/p>\n<p>\\[ \\Phi = B \\cdot A \\cdot \\cos(\\theta) = 0.005 \\times 0.02 \\times \\cos(30^\\circ) = 0.0001 \\times 0.8660 \\approx 8.66 \\times 10^{-5}\\ \\text{Wb} \\]<\/p>\n<p><strong>Result:<\/strong> \\(\\Phi \\approx 8.66 \\times 10^{-5}\\) Wb, which is 0.0866 mWb or about 86.6 \u00b5Wb. You can reproduce this with the calculator's default values (B = 5 mT, A = 200 cm\u00b2, \u03b8 = 30\u00b0).<\/p>\n<p>\n\r\n<\/section>\n<h2>How to Use the Calculator<\/h2>\n<ol>\n<li>Enter the <strong>Magnetic Flux Density (B)<\/strong> and select its unit (\u00b5T, mT, T or G).<\/li>\n<li>Enter the <strong>Loop Area (A)<\/strong> and choose the area unit (mm\u00b2, cm\u00b2, m\u00b2, in\u00b2 or ft\u00b2).<\/li>\n<li>Enter the <strong>Angle to Surface Normal (\u03b8)<\/strong> in degrees, from 0 to 180. This is the angle between the field direction and the line perpendicular to the loop's surface \u2014 not the angle between the field and the plane of the loop.<\/li>\n<li>Read the <strong>Magnetic Flux<\/strong> result in webers, together with the same value in millawebers (mWb) and microwebers (\u00b5Wb), plus a step-by-step breakdown in the calculation details.<\/li>\n<\/ol>\n<h2>What Is Magnetic Flux?<\/h2>\n<p>Magnetic flux measures how much of a magnetic field passes through a given surface, such as the area enclosed by a wire loop. Picture the field lines of a magnet: the flux counts how many of those lines cross the loop. A strong field perpendicular to the loop produces a large flux; the same field parallel to the loop's plane produces zero flux, because no field lines actually pass through it.<\/p>\n<p>The angle \\(\\theta\\) in the formula is measured from the <em>normal<\/em> to the surface \u2014 the imaginary line sticking straight out of the loop. When the field is aligned with the normal (\\(\\theta = 0^\\circ\\)), the flux is maximal and equals \\(B \\cdot A\\). When the field lies in the plane of the loop (\\(\\theta = 90^\\circ\\)), \\(\\cos(90^\\circ) = 0\\) and no flux passes through. Angles between 90\u00b0 and 180\u00b0 give a negative flux, which simply means the field passes through the loop in the opposite direction.<\/p>\n<p>Magnetic flux is central to electromagnetism. A <em>changing<\/em> flux through a loop induces an electromotive force (voltage) in it \u2014 this is Faraday's law of induction, the principle behind electric generators, transformers and induction cooktops. If you then need the induced voltage itself, use our <a href=\"https:\/\/wpcalc.com\/en\/physics\/faradays-law-calculator\/\">Faraday's Law calculator<\/a>; for the force a magnetic field exerts on a moving charge in that field, see the <a href=\"https:\/\/wpcalc.com\/en\/physics\/magnetic-force-on-a-moving-charge-calculator\/\">Magnetic Force on a Moving Charge calculator<\/a>.<\/p>\n<h2>Interpreting the Result<\/h2>\n<p>The calculator returns flux in webers (Wb), the SI unit, as well as in millawebers and microwebers for convenience, since everyday flux values are often small \u2014 a 5 mT field through a 200 cm\u00b2 loop yields only about 86.6 \u00b5Wb. A negative result is not an error: it indicates that the field crosses the surface opposite to the chosen normal direction. If you swap the normal to the other side of the loop, the sign flips while the magnitude stays the same.<\/p>\n<p>For a loop with <em>N<\/em> turns of wire (a coil), the total flux linkage is simply \\(N\\Phi\\), since the same flux passes through each turn when the turns are tightly wound and share the same area.<\/p>\n<h2>Assumptions and Limitations<\/h2>\n<ul>\n<li><strong>Uniform field:<\/strong> the formula assumes the magnetic flux density \\(B\\) is the same everywhere over the loop. If the field varies (e.g. near a magnet's pole), the result is only an approximation based on an average value.<\/li>\n<li><strong>Flat loop:<\/strong> the loop is treated as a flat (planar) surface. Strongly curved or deformable loops need a different treatment, since the angle varies across the surface.<\/li>\n<li><strong>Angle from the normal:<\/strong> remember that \\(\\theta\\) is measured from the perpendicular to the loop, not from the loop's plane. If a problem gives the angle from the plane, subtract it from 90\u00b0 before entering it.<\/li>\n<li><strong>Static situation:<\/strong> the calculator gives the flux at a single instant. Only a change of flux over time induces a voltage \u2014 see the <a href=\"https:\/\/wpcalc.com\/en\/physics\/faradays-law-calculator\/\">Faraday's Law calculator<\/a> for induced EMF.<\/li>\n<li><strong>Units:<\/strong> gauss (G) is accepted for convenience (1 G = 10<sup>\u22124<\/sup> T); all inputs are converted to SI internally.<\/li>\n<\/ul>\n<h2>Quick Reference: Flux vs. Angle<\/h2>\n<p>For \\(B = 0.005\\ \\text{T}\\) and \\(A = 0.02\\ \\text{m}^2\\) (\\(B \\cdot A = 10^{-4}\\ \\text{Wb}\\)):<\/p>\n<table>\n<thead>\n<tr>\n<th>\u03b8 (degrees)<\/th>\n<th>cos(\u03b8)<\/th>\n<th>Flux \u03a6 (\u00b5Wb)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>0\u00b0<\/td>\n<td>1.000<\/td>\n<td>100.0<\/td>\n<\/tr>\n<tr>\n<td>30\u00b0<\/td>\n<td>0.866<\/td>\n<td>86.6<\/td>\n<\/tr>\n<tr>\n<td>45\u00b0<\/td>\n<td>0.707<\/td>\n<td>70.7<\/td>\n<\/tr>\n<tr>\n<td>60\u00b0<\/td>\n<td>0.500<\/td>\n<td>50.0<\/td>\n<\/tr>\n<tr>\n<td>90\u00b0<\/td>\n<td>0.000<\/td>\n<td>0.0<\/td>\n<\/tr>\n<tr>\n<td>120\u00b0<\/td>\n<td>\u22120.500<\/td>\n<td>\u221250.0<\/td>\n<\/tr>\n<tr>\n<td>180\u00b0<\/td>\n<td>\u22121.000<\/td>\n<td>\u2212100.0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>This table shows the cosine dependence clearly: flux falls smoothly from its maximum to zero as the loop rotates from perpendicular to parallel, then becomes negative as it turns past 90\u00b0. Related field calculations you may find useful include the <a href=\"https:\/\/wpcalc.com\/en\/physics\/electric-field-of-a-point-charge-calculator\/\">Electric Field of a Point Charge calculator<\/a> and the <a href=\"https:\/\/wpcalc.com\/en\/physics\/parallel-plate-capacitor-calculator\/\">Parallel Plate Capacitor calculator<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Calculate the magnetic flux through a loop from field strength (B), loop area (A) and the angle to the surface normal. Enter values in any unit and get flux in webers, millawebers and microwebers.<\/p>\n","protected":false},"author":3168,"featured_media":0,"comment_status":"open","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[62],"tags":[91],"class_list":["post-66969","post","type-post","status-publish","format-standard","hentry","category-physics","tag-energy-work"],"acf":[],"_links":{"self":[{"href":"https:\/\/wpcalc.com\/en\/wp-json\/wp\/v2\/posts\/66969","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wpcalc.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/wpcalc.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/wpcalc.com\/en\/wp-json\/wp\/v2\/users\/3168"}],"replies":[{"embeddable":true,"href":"https:\/\/wpcalc.com\/en\/wp-json\/wp\/v2\/comments?post=66969"}],"version-history":[{"count":1,"href":"https:\/\/wpcalc.com\/en\/wp-json\/wp\/v2\/posts\/66969\/revisions"}],"predecessor-version":[{"id":66970,"href":"https:\/\/wpcalc.com\/en\/wp-json\/wp\/v2\/posts\/66969\/revisions\/66970"}],"wp:attachment":[{"href":"https:\/\/wpcalc.com\/en\/wp-json\/wp\/v2\/media?parent=66969"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/wpcalc.com\/en\/wp-json\/wp\/v2\/categories?post=66969"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/wpcalc.com\/en\/wp-json\/wp\/v2\/tags?post=66969"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}