{"id":5310,"date":"2026-10-15T06:35:08","date_gmt":"2026-10-15T03:35:08","guid":{"rendered":"https:\/\/wpcalc.com\/es\/ingenieria\/dimensionado-interruptor-termomagnetico\/"},"modified":"2026-10-15T06:35:08","modified_gmt":"2026-10-15T03:35:08","slug":"dimensionado-interruptor-termomagnetico","status":"publish","type":"post","link":"https:\/\/wpcalc.com\/es\/ingenieria\/dimensionado-interruptor-termomagnetico\/","title":{"rendered":"Dimensionado del interruptor termomagn\u00e9tico"},"content":{"rendered":"<section class=\"not-prose calculator-box\" aria-labelledby=\"calculator-title\"><div class=\"flex items-baseline sm:items-center justify-between gap-2 sm:gap-3\"><div class=\"flex flex-col sm:flex-row sm:items-center gap-2\"><span class=\"icon icon-calculator text-primary-700! text-base! dark:text-primary-300!\" aria-hidden=\"true\"><\/span><h2 id=\"calculator-title\" class=\"text-lg font-display font-bold\">Dimensionado del interruptor para una carga conocida<\/h2><\/div><div class=\"calcdash-favorite group\">\n  <button type=\"button\" class=\"favorite\" id=\"favorite\" data-favorite-id=\"5310\" data-favorite-title=\"Interruptor termomagn\u00e9tico\" data-favorite-url=\"https:\/\/wpcalc.com\/es\/ingenieria\/dimensionado-interruptor-termomagnetico\/\" data-favorite-excerpt=\"Calcula el interruptor termomagn\u00e9tico adecuado para cualquier carga. Introduce la potencia (o la corriente) de la carga, la tensi\u00f3n, el n\u00famero de fases y el factor de potencia, y la calculadora aplica la regla del 125 % para cargas continuas y redondea al calibre normalizado superior m\u00e1s cercano seg\u00fan la NEC.\" aria-label=\"A\u00f1adir a favoritos\" data-favorite-icon=\"icon icon-electrical\">\n    <span class=\"icon icon-shape-star-empty\" aria-hidden=\"true\"><\/span>\n  <\/button>\n  <div class=\"calcdash-favorite__tip\" aria-hidden=\"true\">\n   <span class=\"favorite-tooltip\" id=\"favorite-tooltip\"><\/span>\n  <\/div>\n  <span class=\"sr-only\" role=\"status\" id=\"favorite-status\"><\/span>\n<\/div><\/div><form action=\"https:\/\/wpcalc.com\/es\/ingenieria\/dimensionado-interruptor-termomagnetico\/\" method=\"POST\" class=\"calculator\" id=\"calculator-5310\" data-post=\"5310\"><fieldset class=\"fieldset-input is-2\"><legend class=\"sr-only\">Campos de entrada<\/legend><div class=\"field is-single\" id=\"input-1\"><label for=\"field-1\">Dato conocido<\/label><div class=\"grid grid-cols-1\"><select id=\"field-1\" name=\"dato_conocido\"><option value=\"power\" selected>Potencia de la carga (W \/ kW)<\/option><option value=\"current\">Corriente de la carga (A)<\/option><\/select><svg class=\"pointer-events-none col-start-1 row-start-1 mr-2 size-5 self-center justify-self-end text-gray-500 sm:size-4\" viewBox=\"0 0 16 16\" fill=\"currentColor\" aria-hidden=\"true\" data-slot=\"icon\">\n              <path fill-rule=\"evenodd\" d=\"M4.22 6.22a.75.75 0 0 1 1.06 0L8 8.94l2.72-2.72a.75.75 0 1 1 1.06 1.06l-3.25 3.25a.75.75 0 0 1-1.06 0L4.22 7.28a.75.75 0 0 1 0-1.06Z\" clip-rule=\"evenodd\" \/>\n            <\/svg><\/div><\/div><div class=\"field has-term\" id=\"input-2\"><label for=\"field-2\">Potencia de la carga (P)<\/label><div class=\"term\">P<\/div>  <div class=\"absolute bottom-0 left-16 top-8 w-2 h-0.5 bg-blue-500\"><\/div><div class=\"field-group\"><input type=\"text\" name=\"potencia_de_la_carga_p\" id=\"field-2\" aria-describedby=\"calc-info-2\" data-number inputmode=\"decimal\" autocomplete=\"off\" spellcheck=\"false\" min=\"0.1\" value=\"7.2\"\/><div class=\"grid grid-cols-1\"><select id=\"field-3\" name=\"unidad\" aria-label=\"Unidad\"><option value=\"W\">W<\/option><option value=\"kW\" selected>kW<\/option><\/select><svg class=\"pointer-events-none col-start-1 row-start-1 mr-2 size-5 self-center justify-self-end text-gray-500 sm:size-4\" viewBox=\"0 0 16 16\" fill=\"currentColor\" aria-hidden=\"true\" data-slot=\"icon\">\n              <path fill-rule=\"evenodd\" d=\"M4.22 6.22a.75.75 0 0 1 1.06 0L8 8.94l2.72-2.72a.75.75 0 1 1 1.06 1.06l-3.25 3.25a.75.75 0 0 1-1.06 0L4.22 7.28a.75.75 0 0 1 0-1.06Z\" clip-rule=\"evenodd\" \/>\n            <\/svg><\/div><\/div><small id=\"calc-info-2\">Carga total conectada al circuito<\/small><\/div><div class=\"field has-term\" id=\"input-3\"><label for=\"field-4\">Tensi\u00f3n de alimentaci\u00f3n (V)<\/label><div class=\"term\">V<\/div>  <div class=\"absolute bottom-0 left-16 top-8 w-2 h-0.5 bg-blue-500\"><\/div><input type=\"text\" name=\"tensin_de_alimentacin_v\" id=\"field-4\" aria-describedby=\"calc-unit-4 calc-info-4\" data-number inputmode=\"decimal\" autocomplete=\"off\" spellcheck=\"false\" min=\"1\" value=\"240\"\/><div class=\"unit\" id=\"calc-unit-4\">V<\/div><small id=\"calc-info-4\">Tensi\u00f3n entre fases para trif\u00e1sico, entre fase y neutro para monof\u00e1sico<\/small><\/div><div class=\"field\" id=\"input-4\"><label for=\"field-5\">Configuraci\u00f3n de fases<\/label><div class=\"grid grid-cols-1\"><select id=\"field-5\" name=\"configuracin_de_fases\"><option value=\"single\" selected>Single-phase<\/option><option value=\"three\">Trif\u00e1sico<\/option><\/select><svg class=\"pointer-events-none col-start-1 row-start-1 mr-2 size-5 self-center justify-self-end text-gray-500 sm:size-4\" viewBox=\"0 0 16 16\" fill=\"currentColor\" aria-hidden=\"true\" data-slot=\"icon\">\n              <path fill-rule=\"evenodd\" d=\"M4.22 6.22a.75.75 0 0 1 1.06 0L8 8.94l2.72-2.72a.75.75 0 1 1 1.06 1.06l-3.25 3.25a.75.75 0 0 1-1.06 0L4.22 7.28a.75.75 0 0 1 0-1.06Z\" clip-rule=\"evenodd\" \/>\n            <\/svg><\/div><\/div><div class=\"field has-term\" id=\"input-5\"><label for=\"field-6\">Factor de potencia (FP)<\/label><div class=\"term\">FP<\/div>  <div class=\"absolute bottom-0 left-16 top-8 w-2 h-0.5 bg-blue-500\"><\/div><input type=\"text\" name=\"factor_de_potencia_fp\" id=\"field-6\" aria-describedby=\"calc-info-6\" data-number inputmode=\"decimal\" autocomplete=\"off\" spellcheck=\"false\" min=\"0.1\" max=\"1\" value=\"1\"\/><small id=\"calc-info-6\">Usa 1,0 para cargas resistivas, salvo que conozcas el valor real<\/small><\/div><div class=\"field has-term\" id=\"input-6\" hidden><label for=\"field-7\">Corriente de la carga (I)<\/label><div class=\"term\">I<\/div>  <div class=\"absolute bottom-0 left-16 top-8 w-2 h-0.5 bg-blue-500\"><\/div><input type=\"text\" name=\"corriente_de_la_carga_i\" id=\"field-7\" aria-describedby=\"calc-unit-7 calc-info-7\" data-number inputmode=\"decimal\" autocomplete=\"off\" spellcheck=\"false\" min=\"0.01\" value=\"30\"\/><div class=\"unit\" id=\"calc-unit-7\">A<\/div><small id=\"calc-info-7\">Corriente a plena carga que consume el equipo<\/small><\/div><div class=\"field is-checkbox is-single\" id=\"input-7\"><input type=\"checkbox\" id=\"field-8\" value=\"1\" checked=\"checked\"\/><label for=\"field-8\">Carga continua \u2014 dimensionar al 125 %<\/label><\/div><\/fieldset><div class=\"buttons\"><button type=\"submit\" data-text=\"Recalcular\" id=\"calculate-button\" data-post=\"5310\">Calcular<\/button><button type=\"reset\">Restablecer<\/button><\/div><div class=\"field is-checkbox hidden!\" id=\"field-auto-calc\"><input type=\"checkbox\" id=\"auto-calc\"><label for=\"auto-calc\">Calcular autom\u00e1ticamente<\/label><small>Si est\u00e1 activado, el resultado se actualizar\u00e1 autom\u00e1ticamente al cambiar cualquier valor.<\/small><\/div><div class=\"fieldset-result is-hidden\" aria-labelledby=\"result-title\" aria-live=\"polite\" role=\"region\"> <h3 class=\"result-title bg-gradient-to-r from-primary-50 to-gray-50 dark:from-primary-900 dark:to-gray-800\" id=\"result-title\"><span class=\"icon icon-s-pulse\" aria-hidden=\"true\"><\/span> Resultados del dimensionado<\/h3><div class=\"result-box\"><div class=\"field-result\" id=\"output-1\"><span class=\"field-title\"><span>Corriente de carga calculada<\/span><span class=\"result-term\">I<\/span><\/span><span class=\"field-value\" id=\"result-1\" data-unit=\"A\"><\/span><button type=\"button\" class=\"copy-result\" data-tooltip=\"Copiar resultado\" aria-label=\"Copiar resultado\"><span class=\"copy-icon icon icon-document-copy\" aria-hidden=\"true\"><\/span><\/button><\/div><div class=\"field-result\" id=\"output-2\"><span class=\"field-title\"><span>Calibre nominal m\u00ednimo del interruptor<\/span><\/span><span class=\"field-value\" id=\"result-2\" data-unit=\"A\"><\/span><button type=\"button\" class=\"copy-result\" data-tooltip=\"Copiar resultado\" aria-label=\"Copiar resultado\"><span class=\"copy-icon icon icon-document-copy\" aria-hidden=\"true\"><\/span><\/button><\/div><div class=\"field-result is-column\" id=\"output-3\"><span class=\"field-title\"><span>Detalles del c\u00e1lculo<\/span><\/span><span class=\"field-value\" id=\"result-3\"><\/span><button type=\"button\" class=\"copy-result\" data-tooltip=\"Copiar resultado\" aria-label=\"Copiar resultado\"><span class=\"copy-icon icon icon-document-copy\" aria-hidden=\"true\"><\/span><\/button><\/div><\/div><div class=\"result-actions\"><button type=\"button\" class=\"copy-link\"><svg viewBox=\"0 0 20 20\" fill=\"currentColor\" aria-hidden=\"true\"><path d=\"M12.232 4.232a2.5 2.5 0 0 1 3.536 3.536l-1.225 1.224a.75.75 0 0 0 1.061 1.06l1.224-1.224a4 4 0 0 0-5.656-5.656l-3 3a4 4 0 0 0 .225 5.865.75.75 0 0 0 .977-1.138 2.5 2.5 0 0 1-.142-3.667l3-3Z\"\/><path d=\"M11.603 7.963a.75.75 0 0 0-.977 1.138 2.5 2.5 0 0 1 .142 3.667l-3 3a2.5 2.5 0 0 1-3.536-3.536l1.225-1.224a.75.75 0 0 0-1.061-1.06l-1.224 1.224a4 4 0 1 0 5.656 5.656l3-3a4 4 0 0 0-.225-5.865Z\"\/><\/svg><span class=\"copy-link__text\">Copiar enlace a este c\u00e1lculo<\/span><\/button><span class=\"sr-only\" role=\"status\" id=\"copy-link-status\"><\/span><\/div><\/div><a href=\"#respond\" class=\"hidden transition-opacity duration-300 opacity-0 w-50 text-sm justify-center items-center gap-2 px-4 py-2 rounded bg-gray-200 text-gray-700 hover:bg-gray-300\" id=\"leave-comment\"><span class=\"icon icon-comments\" aria-hidden=\"true\"><\/span>Dejar un comentario<\/a><\/form><\/section><section id=\"calc-reactions\" class=\"not-prose hidden my-12 bg-gradient-to-r from-primary-50 to-gray-50 border border-indigo-100 rounded-xl px-6 py-4 shadow-sm\" data-post=\"5310\" aria-live=\"polite\" aria-labelledby=\"calc-reactions-title\"><p id=\"calc-reactions-title\" class=\"text-sm text-gray-500 text-center mb-2\">\u00bfQu\u00e9 te ha parecido este resultado?<\/p><div role=\"group\" aria-labelledby=\"calc-reactions-title\" class=\"grid grid-cols-3 sm:flex sm:flex-row sm:justify-around gap-4 sm:items-center sm:flex-wrap\"><button type=\"button\" aria-pressed=\"false\" class=\"reaction-btn flex flex-col items-center gap-1 text-sm text-gray-700 hover:text-primary-600 cursor-pointer transition-transform hover:scale-105\" data-reaction=\"like\"><span class=\"reaction-count\" data-reaction-count=\"like\">0<\/span><span class=\"reaction text-3xl\" aria-hidden=\"true\">\ud83d\ude00 <\/span><span class=\"reaction-description font-medium\">Me gusta <\/span><\/button><button type=\"button\" aria-pressed=\"false\" class=\"reaction-btn flex flex-col items-center gap-1 text-sm text-gray-700 hover:text-primary-600 cursor-pointer transition-transform hover:scale-105\" data-reaction=\"helpful\"><span class=\"reaction-count\" data-reaction-count=\"helpful\">0<\/span><span class=\"reaction text-3xl\" aria-hidden=\"true\">\ud83d\udca1 <\/span><span class=\"reaction-description font-medium\">\u00datil <\/span><\/button><button type=\"button\" aria-pressed=\"false\" class=\"reaction-btn flex flex-col items-center gap-1 text-sm text-gray-700 hover:text-primary-600 cursor-pointer transition-transform hover:scale-105\" data-reaction=\"confused\"><span class=\"reaction-count\" data-reaction-count=\"confused\">0<\/span><span class=\"reaction text-3xl\" aria-hidden=\"true\">\ud83d\ude15 <\/span><span class=\"reaction-description font-medium\">Confuso <\/span><\/button><button type=\"button\" aria-pressed=\"false\" class=\"reaction-btn flex flex-col items-center gap-1 text-sm text-gray-700 hover:text-primary-600 cursor-pointer transition-transform hover:scale-105\" data-reaction=\"disappointed\"><span class=\"reaction-count\" data-reaction-count=\"disappointed\">0<\/span><span class=\"reaction text-3xl\" aria-hidden=\"true\">\ud83d\ude1e <\/span><span class=\"reaction-description font-medium\">Decepcionado <\/span><\/button><button type=\"button\" aria-pressed=\"false\" class=\"reaction-btn flex flex-col items-center gap-1 text-sm text-gray-700 hover:text-primary-600 cursor-pointer transition-transform hover:scale-105\" data-reaction=\"inaccurate\"><span class=\"reaction-count\" data-reaction-count=\"inaccurate\">0<\/span><span class=\"reaction text-3xl\" aria-hidden=\"true\">\u274c <\/span><span class=\"reaction-description font-medium\">Inexacto <\/span><\/button><\/div><div id=\"reaction-message\" class=\"hidden mt-8 rounded-md border border-primary-100 bg-white\/50 backdrop-blur-sm px-4 py-2 text-sm text-center shadow-sm\"><\/div><\/section><div class=\"calcdash-ad not-prose calcdash-ad--calc_result calcdash-ad--in-article\"><ins class=\"adsbygoogle\" style=\"display:block\" data-ad-client=\"ca-pub-1721569815777345\" data-ad-slot=\"6317458308\" data-ad-layout=\"in-article\" data-ad-format=\"fluid\"><\/ins><script>(adsbygoogle = window.adsbygoogle || []).push({});<\/script><\/div>\n<style id=\"wpcoderpro-inline-1\">.formula-box {\r\n\tborder-bottom: none !important;\r\n}<\/style><section class=\"formula-box\" aria-labelledby=\"formula-title\">\r\n\t<div id=\"formula-title\" class=\"not-prose font-display mb-4\"><span class=\"icon icon-formula\" aria-hidden=\"true\"><\/span><h2>Dimensionado del interruptor termomagn\u00e9tico<\/h2><\/div>\r\n\t<figure class=\"not-prose formula\">\r\n\t\t<figcaption class=\"formula-title\">F\u00f3rmula<\/figcaption>\r\n\t\t<div class=\"text-base text-gray-800\" id=\"formula\">\n\\[ I_{single} = \\frac{P}{V \\cdot PF} \\qquad I_{three} = \\frac{P}{\\sqrt{3} \\cdot V \\cdot PF} \\]\n\\[ I_{required} = 1.25 \\cdot I \\quad (\\text{carga continua}), \\qquad I_{required} = I \\quad (\\text{carga no continua}) \\]\n<\/div>\r\n\t<\/figure>\r\n\t<\/p>\n<p><strong>Donde:<\/strong><\/p>\n<ul>\n<li>\\(P\\) \u2014 potencia de la carga en vatios (W)<\/li>\n<li>\\(V\\) \u2014 tensi\u00f3n de alimentaci\u00f3n en voltios (V): fase-neutro en monof\u00e1sico y entre fases en trif\u00e1sico<\/li>\n<li>\\(PF\\) \u2014 factor de potencia de la carga (0,1\u20131,0)<\/li>\n<li>\\(I\\) \u2014 corriente a plena carga en amperios (A)<\/li>\n<\/ul>\n<p>La primera f\u00f3rmula convierte la potencia de la carga en la corriente que el interruptor debe soportar; la segunda aplica la regla de la NEC 210.20(A), seg\u00fan la cual una carga continua (3 horas o m\u00e1s al m\u00e1ximo) no puede superar el 80 % del calibre del interruptor, lo que equivale a dimensionar el interruptor al 125 % de la corriente de la carga. El calibre necesario se redondea despu\u00e9s al valor normalizado m\u00e1s cercano de la serie de la NEC 240.6(A): 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100, 110, 125, 150, 175, 200, 225, 250, 300, 350, 400, 450, 500, 600, 700, 800, 1000, 1200, 1600 y 2000 A.<\/p>\n<p>\r\n<\/section>\n<style id=\"wpcoderpro-inline-2\">.calculation-box {\r\n\tborder-bottom: none !important;\r\n}<\/style><section id=\"calculation\" class=\"calculation-box\" aria-labelledby=\"calculation-title\">\r\n\t<div id=\"calculation-title\" class=\"not-prose font-display\"><span class=\"icon icon-unordered-list\" aria-hidden=\"true\"><\/span><h2>Interruptor termomagn\u00e9tico: ejemplo de c\u00e1lculo<\/h2><\/div>\r\n\r\n<\/p>\n<p><strong>Ejemplo:<\/strong> una carga monof\u00e1sica continua de 7,2 kW a una tensi\u00f3n de 240 V con factor de potencia 1,0 (los valores por defecto de la calculadora).<\/p>\n<p>\\[ I = \\frac{P}{V \\cdot PF} = \\frac{7200\\ \\. W}{240\\ \\. V \\cdot 1.0} = 30\\ \\. A \\]<\/p>\n<p>\\[ I_{required} = 1.25 \\cdot 30 = 37.5\\ \\. A \\]<\/p>\n<p>El menor calibre normalizado que no queda por debajo de 37,5 A es <strong>40 A<\/strong>.<\/p>\n<p><strong>Resultado:<\/strong> corriente de carga calculada = 30 A; calibre nominal m\u00ednimo del interruptor = 40 A (potencia aparente \u2248 7,2 kVA).<\/p>\n<p>\n\r\n<\/section>\n<h2>C\u00f3mo usar la calculadora de dimensionado del interruptor termomagn\u00e9tico<\/h2>\n<ol>\n<li>Elige la <strong>magnitud conocida<\/strong>: selecciona \u00abPotencia de la carga (W \/ kW)\u00bb si conoces la potencia del equipo, o \u00abCorriente de la carga (A)\u00bb si la placa de caracter\u00edsticas indica directamente la corriente a plena carga.<\/li>\n<li>Si has elegido potencia, introduce la <strong>potencia de la carga (P)<\/strong> y selecciona la unidad (W o kW). Si has elegido corriente, introduce la <strong>corriente de la carga (I)<\/strong> en amperios, tomada de la placa de caracter\u00edsticas del equipo.<\/li>\n<li>Introduce la <strong>tensi\u00f3n de alimentaci\u00f3n (V)<\/strong>: la tensi\u00f3n fase-neutro en un circuito monof\u00e1sico (p. ej. 120 V o 230 V) o la tensi\u00f3n entre fases en un circuito trif\u00e1sico (p. ej. 400 V o 480 V).<\/li>\n<li>Fija la <strong>configuraci\u00f3n de fases<\/strong> en monof\u00e1sico o trif\u00e1sico.<\/li>\n<li>Introduce el <strong>factor de potencia (PF)<\/strong>. Usa 1,0 para cargas resistivas como calefactores e iluminaci\u00f3n incandescente; para motores, fuentes de alimentaci\u00f3n y otros equipos inductivos emplea el valor de la placa si lo conoces (normalmente 0,8\u20130,9). Un factor de potencia m\u00e1s bajo implica m\u00e1s corriente para la misma potencia, as\u00ed que una estimaci\u00f3n baja y conservadora es m\u00e1s segura que 1,0.<\/li>\n<li>Deja marcada la casilla <strong>Carga continua \u2014 dimensionar al 125 %<\/strong> si la carga funciona 3 horas o m\u00e1s a su corriente m\u00e1xima (cargadores de veh\u00edculo el\u00e9ctrico, calentadores de agua, compresores). Desm\u00e1rcala solo para cargas de corta duraci\u00f3n o intermitentes.<\/li>\n<li>Lee los resultados: la <strong>corriente de carga calculada<\/strong>, el <strong>calibre nominal m\u00ednimo del interruptor<\/strong> de la serie normalizada de la NEC y un desglose detallado que muestra cada paso del c\u00e1lculo.<\/li>\n<\/ol>\n<h2>Qu\u00e9 significa dimensionar un interruptor y por qu\u00e9 es importante<\/h2>\n<p>Un interruptor termomagn\u00e9tico protege el cableado y los equipos de un circuito contra las sobrecorrientes. Si la corriente supera lo que los conductores pueden transportar con seguridad, el aislamiento se sobrecalienta, una de las principales causas de incendios el\u00e9ctricos. El interruptor debe ser, por tanto, lo bastante peque\u00f1o para disparar antes de que el cableado sufra da\u00f1os, pero lo bastante grande para soportar indefinidamente la corriente de carga normal sin disparos intempestivos, incluidas las corrientes de arranque de motores y fuentes de alimentaci\u00f3n.<\/p>\n<p>El c\u00e1lculo tiene dos partes. Primero se determina la corriente real de la carga, bien a partir de la placa de caracter\u00edsticas, bien dividiendo la potencia entre la tensi\u00f3n (y, en cargas de corriente alterna, entre el factor de potencia). Despu\u00e9s se aplica el factor de dimensionado: el National Electrical Code (NEC 210.20(A)) limita una carga continua al 80 % del calibre del dispositivo de protecci\u00f3n, de modo que una carga continua exige un interruptor de al menos el 125 % de su corriente. Por ejemplo, una carga continua de 30 A necesita un interruptor de al menos 37,5 A, que se redondea a un calibre normalizado de 40 A.<\/p>\n<p>El resultado final siempre se redondea hacia arriba a un calibre nominal normalizado, porque los interruptores solo se fabrican en tama\u00f1os fijos recogidos en la NEC 240.6(A): 15, 20, 25, 30, 35, 40, 45, 50, 60 A, y as\u00ed hasta 2000 A. La calculadora elige siempre el menor calibre normalizado que iguale o supere el valor necesario, y nunca baja de 15 A, el interruptor normalizado m\u00e1s peque\u00f1o.<\/p>\n<p>Interpretar el resultado es sencillo: el n\u00famero que se muestra es el calibre m\u00ednimo aceptable del interruptor. Puedes usar un calibre mayor solo si la ampacidad del conductor y las conexiones de los equipos tambi\u00e9n lo admiten: el interruptor, el cable y las tomas de corriente deben funcionar como un sistema coordinado.<\/p>\n<h2>Supuestos, limitaciones y consejos pr\u00e1cticos<\/h2>\n<ul>\n<li><strong>La ampacidad del conductor importa.<\/strong> Esta calculadora dimensiona \u00fanicamente el interruptor. El cable debe tener una ampacidad al menos igual a la corriente de la carga y, en la mayor\u00eda de los casos, igual o superior al calibre del interruptor. Usa la <a href=\"https:\/\/wpcalc.com\/es\/ingenieria\/calibre-de-cable\/\">calculadora de secci\u00f3n de cable<\/a> para comprobar el conductor adecuado seg\u00fan tu corriente y la longitud del recorrido.<\/li>\n<li><strong>La ca\u00edda de tensi\u00f3n puede obligar a un cable mayor.<\/strong> En recorridos largos, la ca\u00edda de tensi\u00f3n \u2014y no la ampacidad\u2014 suele ser lo que determina la secci\u00f3n del cable. Comprueba el circuito con la <a href=\"https:\/\/wpcalc.com\/es\/ingenieria\/caida-de-tension\/\">calculadora de ca\u00edda de tensi\u00f3n<\/a>.<\/li>\n<li><strong>Los motores y la climatizaci\u00f3n siguen reglas especiales.<\/strong> Los motores (art\u00edculo 430 de la NEC) y los equipos de aire acondicionado (art\u00edculo 440) tienen sus propias tablas de dimensionado basadas en la corriente a plena carga y en las instrucciones del fabricante, que pueden exigir interruptores mayores de lo que sugiere este c\u00e1lculo simple.<\/li>\n<li><strong>La regla del calibre superior inmediato tiene l\u00edmites.<\/strong> La NEC 240.4(B) permite el siguiente calibre normalizado superior para cargas fijas no continuas bajo ciertas condiciones, pero solo cuando la ampacidad del conductor es al menos igual a la corriente de la carga y el incremento no supera el calibre normalizado inmediatamente superior; nunca se aplica a cargas continuas ni a circuitos con tomas para cargas port\u00e1tiles.<\/li>\n<li><strong>Supuestos sobre el factor de potencia.<\/strong> Usar PF = 1,0 en una carga inductiva subestima la corriente. Si el factor de potencia de la placa es desconocido en una carga tipo motor, una suposici\u00f3n conservadora de 0,8 da un resultado m\u00e1s seguro. Un mal factor de potencia tambi\u00e9n puede corregirse en el origen: consulta la <a href=\"https:\/\/wpcalc.com\/es\/ingenieria\/correccion-factor-de-potencia\/\">calculadora de correcci\u00f3n del factor de potencia<\/a>.<\/li>\n<li><strong>Las normas var\u00edan seg\u00fan el pa\u00eds.<\/strong> Esta calculadora sigue las convenciones de la NEC usadas en Norteam\u00e9rica. Las normas basadas en la IEC de otras regiones aplican principios parecidos, pero con calibres normalizados y factores de dimensionado distintos: verifica siempre tu reglamento el\u00e9ctrico local.<\/li>\n<li><strong>La seguridad ante todo.<\/strong> Trabajar en cuadros el\u00e9ctricos implica terminales energizados al descubierto. Haz que un electricista titulado realice o revise la instalaci\u00f3n, y nunca sustituyas un interruptor por uno de mayor calibre sin verificar antes las capacidades del conductor y de los equipos.<\/li>\n<\/ul>\n<h2>Calibres normalizados de interruptores (NEC 240.6(A))<\/h2>\n<table>\n<thead>\n<tr>\n<th>Rango de corriente<\/th>\n<th>Aplicaci\u00f3n t\u00edpica<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>15\u201320 A<\/td>\n<td>Iluminaci\u00f3n, circuitos de tomas de uso general<\/td>\n<\/tr>\n<tr>\n<td>30\u201350 A<\/td>\n<td>Calentadores de agua, secadoras, cocinas, carga de veh\u00edculos el\u00e9ctricos<\/td>\n<\/tr>\n<tr>\n<td>60\u2013100 A<\/td>\n<td>Subcuadros, climatizaci\u00f3n de gran potencia, cargadores r\u00e1pidos de veh\u00edculos el\u00e9ctricos<\/td>\n<\/tr>\n<tr>\n<td>125\u2013400 A<\/td>\n<td>Acometida, distribuci\u00f3n principal<\/td>\n<\/tr>\n<tr>\n<td>400\u20132000 A<\/td>\n<td>Cuadros de distribuci\u00f3n comerciales e industriales<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Para completar el an\u00e1lisis del circuito, la <a href=\"https:\/\/wpcalc.com\/es\/ingenieria\/ley-de-ohm\/\">calculadora de la ley de Ohm<\/a> y la <a href=\"https:\/\/wpcalc.com\/es\/ingenieria\/corriente-de-cortocircuito-presunta\/\">calculadora de corriente de cortocircuito<\/a> cubren la otra cara del dise\u00f1o: comprobar que la capacidad de corte del interruptor es suficiente para la corriente de falta presente en el cuadro.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Calcula el interruptor termomagn\u00e9tico adecuado para cualquier carga. Introduce la potencia (o la corriente) de la carga, la tensi\u00f3n, el n\u00famero de fases y el factor de potencia, y la calculadora aplica la regla del 125 % para cargas continuas y redondea al calibre normalizado superior m\u00e1s cercano seg\u00fan la NEC.<\/p>\n","protected":false},"author":3168,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[9],"tags":[10],"class_list":["post-5310","post","type-post","status-publish","format-standard","hentry","category-ingenieria","tag-electrica"],"acf":[],"_links":{"self":[{"href":"https:\/\/wpcalc.com\/es\/wp-json\/wp\/v2\/posts\/5310","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wpcalc.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/wpcalc.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/wpcalc.com\/es\/wp-json\/wp\/v2\/users\/3168"}],"replies":[{"embeddable":true,"href":"https:\/\/wpcalc.com\/es\/wp-json\/wp\/v2\/comments?post=5310"}],"version-history":[{"count":1,"href":"https:\/\/wpcalc.com\/es\/wp-json\/wp\/v2\/posts\/5310\/revisions"}],"predecessor-version":[{"id":5939,"href":"https:\/\/wpcalc.com\/es\/wp-json\/wp\/v2\/posts\/5310\/revisions\/5939"}],"wp:attachment":[{"href":"https:\/\/wpcalc.com\/es\/wp-json\/wp\/v2\/media?parent=5310"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/wpcalc.com\/es\/wp-json\/wp\/v2\/categories?post=5310"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/wpcalc.com\/es\/wp-json\/wp\/v2\/tags?post=5310"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}