{"id":5810,"date":"2026-10-15T02:46:57","date_gmt":"2026-10-14T23:46:57","guid":{"rendered":"https:\/\/wpcalc.com\/fr\/ingenierie\/relevement-facteur-de-puissance\/"},"modified":"2026-10-15T02:46:57","modified_gmt":"2026-10-14T23:46:57","slug":"relevement-facteur-de-puissance","status":"publish","type":"post","link":"https:\/\/wpcalc.com\/fr\/ingenierie\/relevement-facteur-de-puissance\/","title":{"rendered":"Rel\u00e8vement du facteur de puissance"},"content":{"rendered":"<section class=\"not-prose calculator-box\" aria-labelledby=\"calculator-title\"><div class=\"flex items-baseline sm:items-center justify-between gap-2 sm:gap-3\"><div class=\"flex flex-col sm:flex-row sm:items-center gap-2\"><span class=\"icon icon-calculator text-primary-700! text-base! dark:text-primary-300!\" aria-hidden=\"true\"><\/span><h2 id=\"calculator-title\" class=\"text-lg font-display font-bold\">Dimensionnez une batterie de condensateurs pour am\u00e9liorer votre facteur de puissance<\/h2><\/div><div class=\"calcdash-favorite group\">\n  <button type=\"button\" class=\"favorite\" id=\"favorite\" data-favorite-id=\"5810\" data-favorite-title=\"Rel\u00e8vement du facteur de puissance\" data-favorite-url=\"https:\/\/wpcalc.com\/fr\/ingenierie\/relevement-facteur-de-puissance\/\" data-favorite-excerpt=\"Calculez la puissance de la batterie de condensateurs (en kvar et en \u00b5F) n\u00e9cessaire pour \u00e9lever votre facteur de puissance de sa valeur actuelle \u00e0 une valeur cible. Saisissez la puissance active, les facteurs de puissance actuel et cible, la tension, la fr\u00e9quence et le type de r\u00e9seau.\" aria-label=\"Ajouter aux favoris\" data-favorite-icon=\"icon icon-electrical\">\n    <span class=\"icon icon-shape-star-empty\" aria-hidden=\"true\"><\/span>\n  <\/button>\n  <div class=\"calcdash-favorite__tip\" aria-hidden=\"true\">\n   <span class=\"favorite-tooltip\" id=\"favorite-tooltip\"><\/span>\n  <\/div>\n  <span class=\"sr-only\" role=\"status\" id=\"favorite-status\"><\/span>\n<\/div><\/div><form action=\"https:\/\/wpcalc.com\/fr\/ingenierie\/relevement-facteur-de-puissance\/\" method=\"POST\" class=\"calculator\" id=\"calculator-5810\" data-post=\"5810\"><fieldset class=\"fieldset-input is-2\"><legend class=\"sr-only\">Champs de saisie<\/legend><div class=\"field has-term\" id=\"input-1\"><label for=\"field-1\">Puissance active (P)<\/label><div class=\"term\">P<\/div>  <div class=\"absolute bottom-0 left-16 top-8 w-2 h-0.5 bg-blue-500\"><\/div><div class=\"field-group\"><input type=\"text\" name=\"puissance_active_p\" id=\"field-1\" aria-describedby=\"calc-info-1\" data-number inputmode=\"decimal\" autocomplete=\"off\" spellcheck=\"false\" min=\"0.001\" value=\"50\"\/><div class=\"grid grid-cols-1\"><select id=\"field-2\" name=\"unit_de_puissance\" aria-label=\"Unit\u00e9 de puissance\"><option value=\"W\">W<\/option><option value=\"kW\" selected>kW<\/option><option value=\"MW\">MW<\/option><\/select><svg class=\"pointer-events-none col-start-1 row-start-1 mr-2 size-5 self-center justify-self-end text-gray-500 sm:size-4\" viewBox=\"0 0 16 16\" fill=\"currentColor\" aria-hidden=\"true\" data-slot=\"icon\">\n              <path fill-rule=\"evenodd\" d=\"M4.22 6.22a.75.75 0 0 1 1.06 0L8 8.94l2.72-2.72a.75.75 0 1 1 1.06 1.06l-3.25 3.25a.75.75 0 0 1-1.06 0L4.22 7.28a.75.75 0 0 1 0-1.06Z\" clip-rule=\"evenodd\" \/>\n            <\/svg><\/div><\/div><small id=\"calc-info-1\">Puissance active consomm\u00e9e par la charge<\/small><\/div><div class=\"field has-term\" id=\"input-2\"><label for=\"field-3\">Facteur de puissance actuel<\/label><div class=\"term\">cos \u03c6\u2081<\/div>  <div class=\"absolute bottom-0 left-16 top-8 w-2 h-0.5 bg-blue-500\"><\/div><input type=\"text\" name=\"facteur_de_puissance_actuel\" id=\"field-3\" aria-describedby=\"calc-info-3\" data-number inputmode=\"decimal\" autocomplete=\"off\" spellcheck=\"false\" min=\"0.05\" max=\"1\" value=\"0.75\"\/><small id=\"calc-info-3\">cos(\u03c6) actuel, compris entre 0,05 et 1<\/small><\/div><div class=\"field has-term\" id=\"input-3\"><label for=\"field-4\">Facteur de puissance vis\u00e9<\/label><div class=\"term\">cos \u03c6\u2082<\/div>  <div class=\"absolute bottom-0 left-16 top-8 w-2 h-0.5 bg-blue-500\"><\/div><input type=\"text\" name=\"facteur_de_puissance_vis\" id=\"field-4\" aria-describedby=\"calc-info-4\" data-number inputmode=\"decimal\" autocomplete=\"off\" spellcheck=\"false\" min=\"0.05\" max=\"1\" value=\"0.95\"\/><small id=\"calc-info-4\">cos(\u03c6) souhait\u00e9 apr\u00e8s correction (il doit \u00eatre sup\u00e9rieur au facteur actuel)<\/small><\/div><div class=\"field has-term\" id=\"input-4\"><label for=\"field-5\">Tension d&#039;alimentation<\/label><div class=\"term\">V<\/div>  <div class=\"absolute bottom-0 left-16 top-8 w-2 h-0.5 bg-blue-500\"><\/div><div class=\"field-group\"><input type=\"text\" name=\"tension_dalimentation\" id=\"field-5\" aria-describedby=\"calc-info-5\" data-number inputmode=\"decimal\" autocomplete=\"off\" spellcheck=\"false\" min=\"1\" value=\"400\"\/><div class=\"grid grid-cols-1\"><select id=\"field-6\" name=\"unit_de_tension\" aria-label=\"Unit\u00e9 de tension\"><option value=\"V\" selected>V<\/option><option value=\"kV\">kV<\/option><\/select><svg class=\"pointer-events-none col-start-1 row-start-1 mr-2 size-5 self-center justify-self-end text-gray-500 sm:size-4\" viewBox=\"0 0 16 16\" fill=\"currentColor\" aria-hidden=\"true\" data-slot=\"icon\">\n              <path fill-rule=\"evenodd\" d=\"M4.22 6.22a.75.75 0 0 1 1.06 0L8 8.94l2.72-2.72a.75.75 0 1 1 1.06 1.06l-3.25 3.25a.75.75 0 0 1-1.06 0L4.22 7.28a.75.75 0 0 1 0-1.06Z\" clip-rule=\"evenodd\" \/>\n            <\/svg><\/div><\/div><small id=\"calc-info-5\">Tension entre phases pour les installations triphas\u00e9es<\/small><\/div><div class=\"field has-term\" id=\"input-5\"><label for=\"field-7\">Fr\u00e9quence (f)<\/label><div class=\"term\">f<\/div>  <div class=\"absolute bottom-0 left-16 top-8 w-2 h-0.5 bg-blue-500\"><\/div><input type=\"text\" name=\"frquence_f\" id=\"field-7\" aria-describedby=\"calc-unit-7 calc-info-7\" data-number inputmode=\"decimal\" autocomplete=\"off\" spellcheck=\"false\" min=\"1\" value=\"50\"\/><div class=\"unit\" id=\"calc-unit-7\">Hz<\/div><small id=\"calc-info-7\">Fr\u00e9quence du r\u00e9seau d&#039;alimentation<\/small><\/div><div class=\"field is-single\" id=\"input-6\"><label for=\"field-8\">Type de r\u00e9seau<\/label><div class=\"grid grid-cols-1\"><select id=\"field-8\" name=\"type_de_rseau\"><option value=\"single\">Single-phase<\/option><option value=\"three\" selected>Triphas\u00e9<\/option><\/select><svg class=\"pointer-events-none col-start-1 row-start-1 mr-2 size-5 self-center justify-self-end text-gray-500 sm:size-4\" viewBox=\"0 0 16 16\" fill=\"currentColor\" aria-hidden=\"true\" data-slot=\"icon\">\n              <path fill-rule=\"evenodd\" d=\"M4.22 6.22a.75.75 0 0 1 1.06 0L8 8.94l2.72-2.72a.75.75 0 1 1 1.06 1.06l-3.25 3.25a.75.75 0 0 1-1.06 0L4.22 7.28a.75.75 0 0 1 0-1.06Z\" clip-rule=\"evenodd\" \/>\n            <\/svg><\/div><\/div><\/fieldset><div class=\"buttons\"><button type=\"submit\" data-text=\"Recalculer\" id=\"calculate-button\" data-post=\"5810\">Calculer<\/button><button type=\"reset\">R\u00e9initialiser<\/button><\/div><div class=\"field is-checkbox hidden!\" id=\"field-auto-calc\"><input type=\"checkbox\" id=\"auto-calc\"><label for=\"auto-calc\">Calculer automatiquement<\/label><small>Si activ\u00e9, le r\u00e9sultat se met \u00e0 jour automatiquement d\u00e8s que vous modifiez une valeur.<\/small><\/div><div class=\"fieldset-result is-hidden\" aria-labelledby=\"result-title\" aria-live=\"polite\" role=\"region\"> <h3 class=\"result-title bg-gradient-to-r from-primary-50 to-gray-50 dark:from-primary-900 dark:to-gray-800\" id=\"result-title\"><span class=\"icon icon-s-pulse\" aria-hidden=\"true\"><\/span> R\u00e9sultats du dimensionnement de la batterie de condensateurs<\/h3><div class=\"result-box\"><div class=\"field-result\" id=\"output-1\"><span class=\"field-title\"><span>Puissance r\u00e9active des condensateurs requise<\/span><span class=\"result-term\">Qc<\/span><\/span><span class=\"field-value\" id=\"result-1\" data-unit=\"kvar\"><\/span><button type=\"button\" class=\"copy-result\" data-tooltip=\"Copier le r\u00e9sultat\" aria-label=\"Copier le r\u00e9sultat\"><span class=\"copy-icon icon icon-document-copy\" aria-hidden=\"true\"><\/span><\/button><\/div><div class=\"field-result is-column\" id=\"output-2\"><span class=\"field-title\"><span>Capacit\u00e9 requise (format lisible)<\/span><\/span><span class=\"field-value\" id=\"result-2\"><\/span><button type=\"button\" class=\"copy-result\" data-tooltip=\"Copier le r\u00e9sultat\" aria-label=\"Copier le r\u00e9sultat\"><span class=\"copy-icon icon icon-document-copy\" aria-hidden=\"true\"><\/span><\/button><\/div><div class=\"field-result\" id=\"output-3\"><span class=\"field-title\"><span>Puissance r\u00e9active actuelle<\/span><span class=\"result-term\">Q\u2081<\/span><\/span><span class=\"field-value\" id=\"result-3\" data-unit=\"kvar\"><\/span><button type=\"button\" class=\"copy-result\" data-tooltip=\"Copier le r\u00e9sultat\" aria-label=\"Copier le r\u00e9sultat\"><span class=\"copy-icon icon icon-document-copy\" aria-hidden=\"true\"><\/span><\/button><\/div><div class=\"field-result\" id=\"output-4\"><span class=\"field-title\"><span>Puissance r\u00e9active corrig\u00e9e<\/span><span class=\"result-term\">Q\u2082<\/span><\/span><span class=\"field-value\" id=\"result-4\" data-unit=\"kvar\"><\/span><button type=\"button\" class=\"copy-result\" data-tooltip=\"Copier le r\u00e9sultat\" aria-label=\"Copier le r\u00e9sultat\"><span class=\"copy-icon icon icon-document-copy\" aria-hidden=\"true\"><\/span><\/button><\/div><div class=\"field-result\" id=\"output-5\"><span class=\"field-title\"><span>Puissance apparente actuelle<\/span><span class=\"result-term\">S\u2081<\/span><\/span><span class=\"field-value\" id=\"result-5\" data-unit=\"kVA\"><\/span><button type=\"button\" class=\"copy-result\" data-tooltip=\"Copier le r\u00e9sultat\" aria-label=\"Copier le r\u00e9sultat\"><span class=\"copy-icon icon icon-document-copy\" aria-hidden=\"true\"><\/span><\/button><\/div><div class=\"field-result\" id=\"output-6\"><span class=\"field-title\"><span>Puissance apparente corrig\u00e9e<\/span><span class=\"result-term\">S\u2082<\/span><\/span><span class=\"field-value\" id=\"result-6\" data-unit=\"kVA\"><\/span><button type=\"button\" class=\"copy-result\" data-tooltip=\"Copier le r\u00e9sultat\" aria-label=\"Copier le r\u00e9sultat\"><span class=\"copy-icon icon icon-document-copy\" aria-hidden=\"true\"><\/span><\/button><\/div><div class=\"field-result\" id=\"output-7\"><span class=\"field-title\"><span>Courant en ligne actuel<\/span><span class=\"result-term\">I\u2081<\/span><\/span><span class=\"field-value\" id=\"result-7\" data-unit=\"A\"><\/span><button type=\"button\" class=\"copy-result\" data-tooltip=\"Copier le r\u00e9sultat\" aria-label=\"Copier le r\u00e9sultat\"><span class=\"copy-icon icon icon-document-copy\" aria-hidden=\"true\"><\/span><\/button><\/div><div class=\"field-result\" id=\"output-8\"><span class=\"field-title\"><span>Courant en ligne corrig\u00e9<\/span><span class=\"result-term\">I\u2082<\/span><\/span><span class=\"field-value\" id=\"result-8\" data-unit=\"A\"><\/span><button type=\"button\" class=\"copy-result\" data-tooltip=\"Copier le r\u00e9sultat\" aria-label=\"Copier le r\u00e9sultat\"><span class=\"copy-icon icon icon-document-copy\" aria-hidden=\"true\"><\/span><\/button><\/div><div class=\"field-result\" id=\"output-9\"><span class=\"field-title\"><span>R\u00e9duction du courant<\/span><\/span><span class=\"field-value\" id=\"result-9\" data-unit=\"%\"><\/span><button type=\"button\" class=\"copy-result\" data-tooltip=\"Copier le r\u00e9sultat\" aria-label=\"Copier le r\u00e9sultat\"><span class=\"copy-icon icon icon-document-copy\" aria-hidden=\"true\"><\/span><\/button><\/div><\/div><div class=\"result-actions\"><button type=\"button\" class=\"copy-link\"><svg viewBox=\"0 0 20 20\" fill=\"currentColor\" aria-hidden=\"true\"><path d=\"M12.232 4.232a2.5 2.5 0 0 1 3.536 3.536l-1.225 1.224a.75.75 0 0 0 1.061 1.06l1.224-1.224a4 4 0 0 0-5.656-5.656l-3 3a4 4 0 0 0 .225 5.865.75.75 0 0 0 .977-1.138 2.5 2.5 0 0 1-.142-3.667l3-3Z\"\/><path d=\"M11.603 7.963a.75.75 0 0 0-.977 1.138 2.5 2.5 0 0 1 .142 3.667l-3 3a2.5 2.5 0 0 1-3.536-3.536l1.225-1.224a.75.75 0 0 0-1.061-1.06l-1.224 1.224a4 4 0 1 0 5.656 5.656l3-3a4 4 0 0 0-.225-5.865Z\"\/><\/svg><span class=\"copy-link__text\">Copier le lien vers ce calcul<\/span><\/button><span class=\"sr-only\" role=\"status\" id=\"copy-link-status\"><\/span><\/div><\/div><a href=\"#respond\" class=\"hidden transition-opacity duration-300 opacity-0 w-50 text-sm justify-center items-center gap-2 px-4 py-2 rounded bg-gray-200 text-gray-700 hover:bg-gray-300\" id=\"leave-comment\"><span class=\"icon icon-comments\" aria-hidden=\"true\"><\/span>Laisser un commentaire<\/a><\/form><\/section><section id=\"calc-reactions\" class=\"not-prose hidden my-12 bg-gradient-to-r from-primary-50 to-gray-50 border border-indigo-100 rounded-xl px-6 py-4 shadow-sm\" data-post=\"5810\" aria-live=\"polite\" aria-labelledby=\"calc-reactions-title\"><p id=\"calc-reactions-title\" class=\"text-sm text-gray-500 text-center mb-2\">Que pensez-vous de ce r\u00e9sultat\u00a0?<\/p><div role=\"group\" aria-labelledby=\"calc-reactions-title\" class=\"grid grid-cols-3 sm:flex sm:flex-row sm:justify-around gap-4 sm:items-center sm:flex-wrap\"><button type=\"button\" aria-pressed=\"false\" class=\"reaction-btn flex flex-col items-center gap-1 text-sm text-gray-700 hover:text-primary-600 cursor-pointer transition-transform hover:scale-105\" data-reaction=\"like\"><span class=\"reaction-count\" data-reaction-count=\"like\">0<\/span><span class=\"reaction text-3xl\" aria-hidden=\"true\">\ud83d\ude00 <\/span><span class=\"reaction-description font-medium\">J\u2019aime <\/span><\/button><button type=\"button\" aria-pressed=\"false\" class=\"reaction-btn flex flex-col items-center gap-1 text-sm text-gray-700 hover:text-primary-600 cursor-pointer transition-transform hover:scale-105\" data-reaction=\"helpful\"><span class=\"reaction-count\" data-reaction-count=\"helpful\">0<\/span><span class=\"reaction text-3xl\" aria-hidden=\"true\">\ud83d\udca1 <\/span><span class=\"reaction-description font-medium\">Utile <\/span><\/button><button type=\"button\" aria-pressed=\"false\" class=\"reaction-btn flex flex-col items-center gap-1 text-sm text-gray-700 hover:text-primary-600 cursor-pointer transition-transform hover:scale-105\" data-reaction=\"confused\"><span class=\"reaction-count\" data-reaction-count=\"confused\">0<\/span><span class=\"reaction text-3xl\" aria-hidden=\"true\">\ud83d\ude15 <\/span><span class=\"reaction-description font-medium\">Confus <\/span><\/button><button type=\"button\" aria-pressed=\"false\" class=\"reaction-btn flex flex-col items-center gap-1 text-sm text-gray-700 hover:text-primary-600 cursor-pointer transition-transform hover:scale-105\" data-reaction=\"disappointed\"><span class=\"reaction-count\" data-reaction-count=\"disappointed\">0<\/span><span class=\"reaction text-3xl\" aria-hidden=\"true\">\ud83d\ude1e <\/span><span class=\"reaction-description font-medium\">D\u00e9\u00e7u <\/span><\/button><button type=\"button\" aria-pressed=\"false\" class=\"reaction-btn flex flex-col items-center gap-1 text-sm text-gray-700 hover:text-primary-600 cursor-pointer transition-transform hover:scale-105\" data-reaction=\"inaccurate\"><span class=\"reaction-count\" data-reaction-count=\"inaccurate\">0<\/span><span class=\"reaction text-3xl\" aria-hidden=\"true\">\u274c <\/span><span class=\"reaction-description font-medium\">Inexact <\/span><\/button><\/div><div id=\"reaction-message\" class=\"hidden mt-8 rounded-md border border-primary-100 bg-white\/50 backdrop-blur-sm px-4 py-2 text-sm text-center shadow-sm\"><\/div><\/section><div class=\"calcdash-ad not-prose calcdash-ad--calc_result calcdash-ad--in-article\"><ins class=\"adsbygoogle\" style=\"display:block\" data-ad-client=\"ca-pub-1721569815777345\" data-ad-slot=\"6317458308\" data-ad-layout=\"in-article\" data-ad-format=\"fluid\"><\/ins><script>(adsbygoogle = window.adsbygoogle || []).push({});<\/script><\/div>\n<style id=\"wpcoderpro-inline-1\">.formula-box {\r\n\tborder-bottom: none !important;\r\n}<\/style><section class=\"formula-box\" aria-labelledby=\"formula-title\">\r\n\t<div id=\"formula-title\" class=\"not-prose font-display mb-4\"><span class=\"icon icon-formula\" aria-hidden=\"true\"><\/span><h2>Rel\u00e8vement du facteur de puissance<\/h2><\/div>\r\n\t<figure class=\"not-prose formula\">\r\n\t\t<figcaption class=\"formula-title\">Formule<\/figcaption>\r\n\t\t<div class=\"text-base text-gray-800\" id=\"formula\">\n\\[ Q_C = P\\left(\\tan\\varphi_1 - \\tan\\varphi_2\\right), \\quad \\text{o\u00f9 } \\tan\\varphi = \\tan\\!\\left(\\arccos(\\text{fp})\\right) \\]\n\\[ C = \\frac{Q_C}{\\omega V^2} \\;\\; \\text{(monophas\u00e9)}, \\qquad C = \\frac{Q_C}{3\\,\\omega V^2} \\;\\; \\text{(triphas\u00e9, triangle)}, \\qquad \\omega = 2\\pi f \\]\n<\/div>\r\n\t<\/figure>\r\n\t<\/p>\n<p><strong>O\u00f9&nbsp;:<\/strong><\/p>\n<ul>\n<li>\\(Q_C\\) \u2014 puissance r\u00e9active que la batterie de condensateurs doit fournir (var)<\/li>\n<li>\\(P\\) \u2014 puissance active de la charge (W)<\/li>\n<li>\\(\\varphi_1, \\varphi_2\\) \u2014 d\u00e9phasages avant et apr\u00e8s compensation, d\u00e9duits des facteurs de puissance<\/li>\n<li>\\(C\\) \u2014 capacit\u00e9 par phase (F)<\/li>\n<li>\\(V\\) \u2014 tension d'alimentation&nbsp;: tension compos\u00e9e en triphas\u00e9, tension du r\u00e9seau en monophas\u00e9 (V)<\/li>\n<li>\\(f\\) \u2014 fr\u00e9quence du r\u00e9seau (Hz)<\/li>\n<\/ul>\n<p>La premi\u00e8re formule d\u00e9termine la puissance r\u00e9active que les condensateurs doivent injecter pour annuler l'\u00e9cart entre la demande r\u00e9active actuelle de la charge et la cible&nbsp;; la seconde convertit cette puissance r\u00e9active en une capacit\u00e9 r\u00e9elle, \u00e0 la tension et \u00e0 la fr\u00e9quence indiqu\u00e9es.<\/p>\n<p>\r\n<\/section>\n<style id=\"wpcoderpro-inline-2\">.calculation-box {\r\n\tborder-bottom: none !important;\r\n}<\/style><section id=\"calculation\" class=\"calculation-box\" aria-labelledby=\"calculation-title\">\r\n\t<div id=\"calculation-title\" class=\"not-prose font-display\"><span class=\"icon icon-unordered-list\" aria-hidden=\"true\"><\/span><h2>Rel\u00e8vement du facteur de puissance<\/h2><\/div>\r\n\r\n<\/p>\n<p><strong>Exemple&nbsp;:<\/strong> une charge industrielle triphas\u00e9e absorbe 50 kW avec un facteur de puissance de 0,75 sur un r\u00e9seau 400 V, 50 Hz. D\u00e9terminez la batterie de condensateurs n\u00e9cessaire pour \u00e9lever le facteur de puissance \u00e0 0,95.<\/p>\n<p>\\[ \\tan\\varphi_1 = \\tan(\\arccos 0.75) = 0.8819, \\qquad \\tan\\varphi_2 = \\tan(\\arccos 0.95) = 0.3287 \\]<\/p>\n<p>\\[ Q_C = 50\\,000 \\times (0.8819 - 0.3287) = 27\\,662 \\text{ var} \\approx 27.66 \\text{ kvar} \\]<\/p>\n<p>\\[ C = \\frac{27\\,662}{3 \\times 2\\pi \\times 50 \\times 400^2} = 1.834 \\times 10^{-4}\\text{ F} \\approx 183.4\\ \\mu\\text{F par phase} \\]<\/p>\n<p><strong>R\u00e9sultat :<\/strong> une batterie de condensateurs de 27,66 kvar, r\u00e9alis\u00e9e avec trois condensateurs coupl\u00e9s en triangle d'environ 183 \u00b5F chacun (dimensionn\u00e9s pour la tension compos\u00e9e de 400 V). Le courant en ligne passe de 96,2 A \u00e0 76,0 A \u2014 soit une r\u00e9duction de 21&nbsp;%.<\/p>\n<p>\n\r\n<\/section>\n<h2>Comment utiliser le calculateur<\/h2>\n<ol>\n<li>Saisissez la <strong>puissance active (P)<\/strong> consomm\u00e9e par votre charge et choisissez l'unit\u00e9 (W, kW ou MW). Il s'agit de la puissance active, et non de la puissance apparente figurant sur une facture d'\u00e9lectricit\u00e9.<\/li>\n<li>Saisissez le <strong>facteur de puissance actuel<\/strong> \u2014 le cos(\u03c6) de la charge en ce moment, mesur\u00e9 ou repris d'une facture.<\/li>\n<li>Saisissez le <strong>facteur de puissance cible<\/strong> que vous souhaitez atteindre. Il doit \u00eatre sup\u00e9rieur \u00e0 la valeur actuelle (g\u00e9n\u00e9ralement 0,95 ; au-del\u00e0 de 0,98, le jeu en vaut rarement la chandelle).<\/li>\n<li>Saisissez la <strong>tension d'alimentation (V)<\/strong> avec son unit\u00e9. En triphas\u00e9, utilisez la tension compos\u00e9e (par ex. 400 V).<\/li>\n<li>Saisissez la <strong>fr\u00e9quence (f)<\/strong> en Hz \u2014 50 Hz dans la majeure partie du monde, 60 Hz en Am\u00e9rique du Nord.<\/li>\n<li>Choisissez la <strong>configuration des phases<\/strong>&nbsp;: monophas\u00e9 ou triphas\u00e9. L'option triphas\u00e9e suppose une charge \u00e9quilibr\u00e9e avec des condensateurs coupl\u00e9s en triangle.<\/li>\n<li>Lisez les r\u00e9sultats&nbsp;: la puissance requise de la batterie de condensateurs en kvar, la capacit\u00e9 par phase, ainsi que la comparaison avant\/apr\u00e8s de la puissance r\u00e9active, de la puissance apparente et du courant en ligne.<\/li>\n<\/ol>\n<h2>Qu'est-ce que le rel\u00e8vement du facteur de puissance&nbsp;?<\/h2>\n<p>Le facteur de puissance est le rapport entre la puissance active \\(P\\) (celle qui produit un travail utile) et la puissance apparente \\(S\\) (celle que le r\u00e9seau doit acheminer) : \\( \\text{fp} = P\/S = \\cos\\varphi \\). Les charges inductives \u2014 moteurs, transformateurs, postes \u00e0 souder, \u00e9clairages fluorescents \u2014 absorbent un courant magn\u00e9tisant en retard sur la tension. Ce courant, appel\u00e9 puissance r\u00e9active \\(Q\\), ne produit aucun travail utile, mais il fait des allers-retours dans les c\u00e2bles, les transformateurs et l'appareillage, qu'il \u00e9chauffe et dont il monopolise la capacit\u00e9.<\/p>\n<p>Le rel\u00e8vement du facteur de puissance consiste \u00e0 raccorder des condensateurs en parall\u00e8le avec la charge. Les condensateurs absorbent un courant r\u00e9actif en avance qui compense le courant en retard de l'inductance, de sorte que la puissance r\u00e9active appel\u00e9e sur le r\u00e9seau diminue. La puissance active reste rigoureusement identique \u2014 seule la composante \u00ab&nbsp;gaspill\u00e9e&nbsp;\u00bb du courant est \u00e9limin\u00e9e. G\u00e9om\u00e9triquement, la compensation d\u00e9place le point de fonctionnement de la charge le long d'une droite \u00e0 \\(P\\) constant, jusqu'\u00e0 ce que le d\u00e9phasage \\(\\varphi\\) se r\u00e9duise \u00e0 la valeur cible.<\/p>\n<p>Le courant diminuant dans les m\u00eames proportions que la puissance apparente, la compensation lib\u00e8re directement de la capacit\u00e9&nbsp;: dans l'exemple ci-dessus, des c\u00e2bles qui transportaient 96 A n'en transportent plus que 76 A. Les distributeurs facturent souvent des p\u00e9nalit\u00e9s lorsque le facteur de puissance descend en dessous d'environ 0,90 \u00e0 0,95&nbsp;; une batterie de compensation s'amortit donc fr\u00e9quemment en quelques ann\u00e9es gr\u00e2ce \u00e0 la baisse de ces p\u00e9nalit\u00e9s. La chute de tension le long des longs d\u00e9parts s'am\u00e9liore \u00e9galement, car elle est \u00e0 peu pr\u00e8s proportionnelle au courant en ligne.<\/p>\n<h2>Hypoth\u00e8ses, limites et conseils pratiques<\/h2>\n<ul>\n<li><strong>Charge \u00e9quilibr\u00e9e et lin\u00e9aire.<\/strong> Le calcul triphas\u00e9 suppose des courants identiques dans toutes les phases. Les charges fortement d\u00e9s\u00e9quilibr\u00e9es exigent une mesure et une compensation phase par phase.<\/li>\n<li><strong>Condensateurs coupl\u00e9s en triangle.<\/strong> La capacit\u00e9 obtenue correspond \u00e0 chaque phase pour trois condensateurs coupl\u00e9s en triangle, chacun dimensionn\u00e9 pour la pleine tension compos\u00e9e. Un couplage \u00e9toile exige trois fois plus de capacit\u00e9 par condensateur, mais une tension nominale \u00e9gale \u00e0 la seule tension simple.<\/li>\n<li><strong>Commandez en kvar, pas en \u00b5F.<\/strong> Les condensateurs de compensation du commerce sont sp\u00e9cifi\u00e9s en kvar \u00e0 une tension et une fr\u00e9quence donn\u00e9es. C'est la valeur en kvar que vous commandez ; la capacit\u00e9 sert aux r\u00e9alisations sur mesure et aux v\u00e9rifications.<\/li>\n<li><strong>Ne visez pas trop haut.<\/strong> Compenser au-del\u00e0 d'environ 0,98 co\u00fbte une capacit\u00e9 disproportionn\u00e9e pour un b\u00e9n\u00e9fice minime et expose, \u00e0 faible charge, \u00e0 un facteur de puissance capacitif susceptible de provoquer des surtensions. Les distributeurs exigent g\u00e9n\u00e9ralement un facteur de puissance final de 0,95 inductif.<\/li>\n<li><strong>Harmoniques et d\u00e9saccordement.<\/strong> Dans les usines \u00e9quip\u00e9es de variateurs de vitesse ou d'autres charges non lin\u00e9aires, les condensateurs peuvent entrer en r\u00e9sonance avec l'inductance du r\u00e9seau. Les batteries de condensateurs d\u00e9saccord\u00e9es (avec inductances en s\u00e9rie) constituent la solution standard \u2014 consultez un sp\u00e9cialiste pour ce type d'installation.<\/li>\n<li><strong>Auto-excitation des moteurs.<\/strong> Ne dimensionnez jamais un condensateur raccord\u00e9 directement aux bornes d'un moteur \u00e0 plus d'environ 90&nbsp;% de la puissance r\u00e9active magn\u00e9tisante du moteur, sous peine d'auto-excitation \u00e0 la mise hors tension.<\/li>\n<li><strong>V\u00e9rifiez par la mesure.<\/strong> La puissance active et le facteur de puissance actuel doivent provenir d'un analyseur de qualit\u00e9 de l'\u00e9nergie ou d'une facture, et non d'estimations bas\u00e9es sur les plaques signal\u00e9tiques, car la charge r\u00e9elle varie.<\/li>\n<\/ul>\n<h2>Calculatrices associ\u00e9es<\/h2>\n<p>Pour analyser plus avant le circuit compens\u00e9, vous trouverez utile le <a href=\"https:\/\/wpcalc.com\/fr\/ingenierie\/loi-d-ohm\/\">calculateur de loi d'Ohm<\/a> pour les relations tension\u2013courant, le <a href=\"https:\/\/wpcalc.com\/en\/engineering\/rc-time-constant\/\">calculateur de constante de temps RC<\/a> pour le comportement des condensateurs en courant continu, et le <a href=\"https:\/\/wpcalc.com\/fr\/ingenierie\/frequence-de-resonance-lc\/\">calculateur de fr\u00e9quence de r\u00e9sonance LC<\/a> pour v\u00e9rifier si votre batterie de compensation pourrait interagir avec l'inductance du r\u00e9seau au voisinage d'une fr\u00e9quence harmonique.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Calculez la puissance de la batterie de condensateurs (en kvar et en \u00b5F) n\u00e9cessaire pour \u00e9lever votre facteur de puissance de sa valeur actuelle \u00e0 une valeur cible. Saisissez la puissance active, les facteurs de puissance actuel et cible, la tension, la fr\u00e9quence et le type de r\u00e9seau.<\/p>\n","protected":false},"author":3168,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[8],"tags":[9],"class_list":["post-5810","post","type-post","status-publish","format-standard","hentry","category-ingenierie","tag-electricite"],"acf":[],"_links":{"self":[{"href":"https:\/\/wpcalc.com\/fr\/wp-json\/wp\/v2\/posts\/5810","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wpcalc.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/wpcalc.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/wpcalc.com\/fr\/wp-json\/wp\/v2\/users\/3168"}],"replies":[{"embeddable":true,"href":"https:\/\/wpcalc.com\/fr\/wp-json\/wp\/v2\/comments?post=5810"}],"version-history":[{"count":1,"href":"https:\/\/wpcalc.com\/fr\/wp-json\/wp\/v2\/posts\/5810\/revisions"}],"predecessor-version":[{"id":6075,"href":"https:\/\/wpcalc.com\/fr\/wp-json\/wp\/v2\/posts\/5810\/revisions\/6075"}],"wp:attachment":[{"href":"https:\/\/wpcalc.com\/fr\/wp-json\/wp\/v2\/media?parent=5810"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/wpcalc.com\/fr\/wp-json\/wp\/v2\/categories?post=5810"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/wpcalc.com\/fr\/wp-json\/wp\/v2\/tags?post=5810"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}