{"id":5814,"date":"2026-10-15T03:02:36","date_gmt":"2026-10-15T00:02:36","guid":{"rendered":"https:\/\/wpcalc.com\/fr\/ingenierie\/courant-de-court-circuit-presume\/"},"modified":"2026-10-15T03:02:36","modified_gmt":"2026-10-15T00:02:36","slug":"courant-de-court-circuit-presume","status":"publish","type":"post","link":"https:\/\/wpcalc.com\/fr\/ingenierie\/courant-de-court-circuit-presume\/","title":{"rendered":"Courant de court-circuit pr\u00e9sum\u00e9"},"content":{"rendered":"<section class=\"not-prose calculator-box\" aria-labelledby=\"calculator-title\"><div class=\"flex items-baseline sm:items-center justify-between gap-2 sm:gap-3\"><div class=\"flex flex-col sm:flex-row sm:items-center gap-2\"><span class=\"icon icon-calculator text-primary-700! text-base! dark:text-primary-300!\" aria-hidden=\"true\"><\/span><h2 id=\"calculator-title\" class=\"text-lg font-display font-bold\">Estimation du courant de d\u00e9faut en un point du circuit<\/h2><\/div><div class=\"calcdash-favorite group\">\n  <button type=\"button\" class=\"favorite\" id=\"favorite\" data-favorite-id=\"5814\" data-favorite-title=\"Courant de court-circuit\" data-favorite-url=\"https:\/\/wpcalc.com\/fr\/ingenierie\/courant-de-court-circuit-presume\/\" data-favorite-excerpt=\"Estimez le courant de court-circuit pr\u00e9sum\u00e9 (courant de d\u00e9faut) en un point d&#039;une installation \u00e9lectrique. Saisissez la tension d&#039;alimentation, l&#039;imp\u00e9dance totale jusqu&#039;au point de d\u00e9faut et choisissez triphas\u00e9 ou monophas\u00e9.\" aria-label=\"Ajouter aux favoris\" data-favorite-icon=\"icon icon-electrical\">\n    <span class=\"icon icon-shape-star-empty\" aria-hidden=\"true\"><\/span>\n  <\/button>\n  <div class=\"calcdash-favorite__tip\" aria-hidden=\"true\">\n   <span class=\"favorite-tooltip\" id=\"favorite-tooltip\"><\/span>\n  <\/div>\n  <span class=\"sr-only\" role=\"status\" id=\"favorite-status\"><\/span>\n<\/div><\/div><form action=\"https:\/\/wpcalc.com\/fr\/ingenierie\/courant-de-court-circuit-presume\/\" method=\"POST\" class=\"calculator\" id=\"calculator-5814\" data-post=\"5814\"><fieldset class=\"fieldset-input is-2\"><legend class=\"sr-only\">Champs de saisie<\/legend><div class=\"field is-single\" id=\"input-1\"><label for=\"field-1\">Type de r\u00e9seau<\/label><div class=\"grid grid-cols-1\"><select id=\"field-1\" name=\"type_de_rseau\"><option value=\"three\" selected>Triphas\u00e9 (tension entre phases)<\/option><option value=\"single\">Single-phase (V line-to-neutral)<\/option><\/select><svg class=\"pointer-events-none col-start-1 row-start-1 mr-2 size-5 self-center justify-self-end text-gray-500 sm:size-4\" viewBox=\"0 0 16 16\" fill=\"currentColor\" aria-hidden=\"true\" data-slot=\"icon\">\n              <path fill-rule=\"evenodd\" d=\"M4.22 6.22a.75.75 0 0 1 1.06 0L8 8.94l2.72-2.72a.75.75 0 1 1 1.06 1.06l-3.25 3.25a.75.75 0 0 1-1.06 0L4.22 7.28a.75.75 0 0 1 0-1.06Z\" clip-rule=\"evenodd\" \/>\n            <\/svg><\/div><\/div><div class=\"field has-term\" id=\"input-2\"><label for=\"field-2\">Tension d&#039;alimentation (V)<\/label><div class=\"term\">V<\/div>  <div class=\"absolute bottom-0 left-16 top-8 w-2 h-0.5 bg-blue-500\"><\/div><div class=\"field-group\"><input type=\"text\" name=\"tension_dalimentation_v\" id=\"field-2\" aria-describedby=\"calc-info-2\" data-number inputmode=\"decimal\" autocomplete=\"off\" spellcheck=\"false\" min=\"1.0E-6\" value=\"400\"\/><div class=\"grid grid-cols-1\"><select id=\"field-3\" name=\"unit_de_tension\" aria-label=\"Unit\u00e9 de tension\"><option value=\"V\" selected>V<\/option><option value=\"kV\">kV<\/option><\/select><svg class=\"pointer-events-none col-start-1 row-start-1 mr-2 size-5 self-center justify-self-end text-gray-500 sm:size-4\" viewBox=\"0 0 16 16\" fill=\"currentColor\" aria-hidden=\"true\" data-slot=\"icon\">\n              <path fill-rule=\"evenodd\" d=\"M4.22 6.22a.75.75 0 0 1 1.06 0L8 8.94l2.72-2.72a.75.75 0 1 1 1.06 1.06l-3.25 3.25a.75.75 0 0 1-1.06 0L4.22 7.28a.75.75 0 0 1 0-1.06Z\" clip-rule=\"evenodd\" \/>\n            <\/svg><\/div><\/div><small id=\"calc-info-2\">Tension nominale au point de d\u00e9faut\u00a0: entre phases en triphas\u00e9, entre phase et neutre en monophas\u00e9<\/small><\/div><div class=\"field has-term\" id=\"input-3\"><label for=\"field-4\">Imp\u00e9dance (Z)<\/label><div class=\"term\">Z<\/div>  <div class=\"absolute bottom-0 left-16 top-8 w-2 h-0.5 bg-blue-500\"><\/div><div class=\"field-group\"><input type=\"text\" name=\"impdance_z\" id=\"field-4\" aria-describedby=\"calc-info-4\" data-number inputmode=\"decimal\" autocomplete=\"off\" spellcheck=\"false\" min=\"1.0E-6\" value=\"50\"\/><div class=\"grid grid-cols-1\"><select id=\"field-5\" name=\"unit_dimpdance\" aria-label=\"Unit\u00e9 d&#039;imp\u00e9dance\"><option value=\"m\u03a9\" selected>m\u03a9<\/option><option value=\"\u03a9\">\u03a9<\/option><\/select><svg class=\"pointer-events-none col-start-1 row-start-1 mr-2 size-5 self-center justify-self-end text-gray-500 sm:size-4\" viewBox=\"0 0 16 16\" fill=\"currentColor\" aria-hidden=\"true\" data-slot=\"icon\">\n              <path fill-rule=\"evenodd\" d=\"M4.22 6.22a.75.75 0 0 1 1.06 0L8 8.94l2.72-2.72a.75.75 0 1 1 1.06 1.06l-3.25 3.25a.75.75 0 0 1-1.06 0L4.22 7.28a.75.75 0 0 1 0-1.06Z\" clip-rule=\"evenodd\" \/>\n            <\/svg><\/div><\/div><small id=\"calc-info-4\">Imp\u00e9dance \u00e9quivalente totale de la source, des transformateurs et des c\u00e2bles jusqu&#039;au point de d\u00e9faut<\/small><\/div><\/fieldset><div class=\"buttons\"><button type=\"submit\" data-text=\"Recalculer\" id=\"calculate-button\" data-post=\"5814\">Calculer<\/button><button type=\"reset\">R\u00e9initialiser<\/button><\/div><div class=\"field is-checkbox hidden!\" id=\"field-auto-calc\"><input type=\"checkbox\" id=\"auto-calc\"><label for=\"auto-calc\">Calculer automatiquement<\/label><small>Si activ\u00e9, le r\u00e9sultat se met \u00e0 jour automatiquement d\u00e8s que vous modifiez une valeur.<\/small><\/div><div class=\"fieldset-result is-hidden\" aria-labelledby=\"result-title\" aria-live=\"polite\" role=\"region\"> <h3 class=\"result-title bg-gradient-to-r from-primary-50 to-gray-50 dark:from-primary-900 dark:to-gray-800\" id=\"result-title\"><span class=\"icon icon-s-pulse\" aria-hidden=\"true\"><\/span> Estimation du courant de d\u00e9faut<\/h3><div class=\"result-box\"><div class=\"field-result\" id=\"output-1\"><span class=\"field-title\"><span>Courant de court-circuit pr\u00e9sum\u00e9<\/span><span class=\"result-term\">Isc<\/span><\/span><span class=\"field-value\" id=\"result-1\" data-unit=\"A\"><\/span><button type=\"button\" class=\"copy-result\" data-tooltip=\"Copier le r\u00e9sultat\" aria-label=\"Copier le r\u00e9sultat\"><span class=\"copy-icon icon icon-document-copy\" aria-hidden=\"true\"><\/span><\/button><\/div><div class=\"field-result is-column\" id=\"output-2\"><span class=\"field-title\"><span>Courant (valeur lisible)<\/span><\/span><span class=\"field-value\" id=\"result-2\"><\/span><button type=\"button\" class=\"copy-result\" data-tooltip=\"Copier le r\u00e9sultat\" aria-label=\"Copier le r\u00e9sultat\"><span class=\"copy-icon icon icon-document-copy\" aria-hidden=\"true\"><\/span><\/button><\/div><div class=\"field-result is-column\" id=\"output-3\"><span class=\"field-title\"><span>D\u00e9tails du calcul<\/span><\/span><span class=\"field-value\" id=\"result-3\"><\/span><button type=\"button\" class=\"copy-result\" data-tooltip=\"Copier le r\u00e9sultat\" aria-label=\"Copier le r\u00e9sultat\"><span class=\"copy-icon icon icon-document-copy\" aria-hidden=\"true\"><\/span><\/button><\/div><\/div><div class=\"result-actions\"><button type=\"button\" class=\"copy-link\"><svg viewBox=\"0 0 20 20\" fill=\"currentColor\" aria-hidden=\"true\"><path d=\"M12.232 4.232a2.5 2.5 0 0 1 3.536 3.536l-1.225 1.224a.75.75 0 0 0 1.061 1.06l1.224-1.224a4 4 0 0 0-5.656-5.656l-3 3a4 4 0 0 0 .225 5.865.75.75 0 0 0 .977-1.138 2.5 2.5 0 0 1-.142-3.667l3-3Z\"\/><path d=\"M11.603 7.963a.75.75 0 0 0-.977 1.138 2.5 2.5 0 0 1 .142 3.667l-3 3a2.5 2.5 0 0 1-3.536-3.536l1.225-1.224a.75.75 0 0 0-1.061-1.06l-1.224 1.224a4 4 0 1 0 5.656 5.656l3-3a4 4 0 0 0-.225-5.865Z\"\/><\/svg><span class=\"copy-link__text\">Copier le lien vers ce calcul<\/span><\/button><span class=\"sr-only\" role=\"status\" id=\"copy-link-status\"><\/span><\/div><\/div><a href=\"#respond\" class=\"hidden transition-opacity duration-300 opacity-0 w-50 text-sm justify-center items-center gap-2 px-4 py-2 rounded bg-gray-200 text-gray-700 hover:bg-gray-300\" id=\"leave-comment\"><span class=\"icon icon-comments\" aria-hidden=\"true\"><\/span>Laisser un commentaire<\/a><\/form><\/section><section id=\"calc-reactions\" class=\"not-prose hidden my-12 bg-gradient-to-r from-primary-50 to-gray-50 border border-indigo-100 rounded-xl px-6 py-4 shadow-sm\" data-post=\"5814\" aria-live=\"polite\" aria-labelledby=\"calc-reactions-title\"><p id=\"calc-reactions-title\" class=\"text-sm text-gray-500 text-center mb-2\">Que pensez-vous de ce r\u00e9sultat\u00a0?<\/p><div role=\"group\" aria-labelledby=\"calc-reactions-title\" class=\"grid grid-cols-3 sm:flex sm:flex-row sm:justify-around gap-4 sm:items-center sm:flex-wrap\"><button type=\"button\" aria-pressed=\"false\" class=\"reaction-btn flex flex-col items-center gap-1 text-sm text-gray-700 hover:text-primary-600 cursor-pointer transition-transform hover:scale-105\" data-reaction=\"like\"><span class=\"reaction-count\" data-reaction-count=\"like\">0<\/span><span class=\"reaction text-3xl\" aria-hidden=\"true\">\ud83d\ude00 <\/span><span class=\"reaction-description font-medium\">J\u2019aime <\/span><\/button><button type=\"button\" aria-pressed=\"false\" class=\"reaction-btn flex flex-col items-center gap-1 text-sm text-gray-700 hover:text-primary-600 cursor-pointer transition-transform hover:scale-105\" data-reaction=\"helpful\"><span class=\"reaction-count\" data-reaction-count=\"helpful\">0<\/span><span class=\"reaction text-3xl\" aria-hidden=\"true\">\ud83d\udca1 <\/span><span class=\"reaction-description font-medium\">Utile <\/span><\/button><button type=\"button\" aria-pressed=\"false\" class=\"reaction-btn flex flex-col items-center gap-1 text-sm text-gray-700 hover:text-primary-600 cursor-pointer transition-transform hover:scale-105\" data-reaction=\"confused\"><span class=\"reaction-count\" data-reaction-count=\"confused\">0<\/span><span class=\"reaction text-3xl\" aria-hidden=\"true\">\ud83d\ude15 <\/span><span class=\"reaction-description font-medium\">Confus <\/span><\/button><button type=\"button\" aria-pressed=\"false\" class=\"reaction-btn flex flex-col items-center gap-1 text-sm text-gray-700 hover:text-primary-600 cursor-pointer transition-transform hover:scale-105\" data-reaction=\"disappointed\"><span class=\"reaction-count\" data-reaction-count=\"disappointed\">0<\/span><span class=\"reaction text-3xl\" aria-hidden=\"true\">\ud83d\ude1e <\/span><span class=\"reaction-description font-medium\">D\u00e9\u00e7u <\/span><\/button><button type=\"button\" aria-pressed=\"false\" class=\"reaction-btn flex flex-col items-center gap-1 text-sm text-gray-700 hover:text-primary-600 cursor-pointer transition-transform hover:scale-105\" data-reaction=\"inaccurate\"><span class=\"reaction-count\" data-reaction-count=\"inaccurate\">0<\/span><span class=\"reaction text-3xl\" aria-hidden=\"true\">\u274c <\/span><span class=\"reaction-description font-medium\">Inexact <\/span><\/button><\/div><div id=\"reaction-message\" class=\"hidden mt-8 rounded-md border border-primary-100 bg-white\/50 backdrop-blur-sm px-4 py-2 text-sm text-center shadow-sm\"><\/div><\/section><div class=\"calcdash-ad not-prose calcdash-ad--calc_result calcdash-ad--in-article\"><ins class=\"adsbygoogle\" style=\"display:block\" data-ad-client=\"ca-pub-1721569815777345\" data-ad-slot=\"6317458308\" data-ad-layout=\"in-article\" data-ad-format=\"fluid\"><\/ins><script>(adsbygoogle = window.adsbygoogle || []).push({});<\/script><\/div>\n<style id=\"wpcoderpro-inline-1\">.formula-box {\r\n\tborder-bottom: none !important;\r\n}<\/style><section class=\"formula-box\" aria-labelledby=\"formula-title\">\r\n\t<div id=\"formula-title\" class=\"not-prose font-display mb-4\"><span class=\"icon icon-formula\" aria-hidden=\"true\"><\/span><h2>Formule du courant de court-circuit<\/h2><\/div>\r\n\t<figure class=\"not-prose formula\">\r\n\t\t<figcaption class=\"formula-title\">Formule<\/figcaption>\r\n\t\t<div class=\"text-base text-gray-800\" id=\"formula\">\n\\[ I_{sc} = \\frac{V}{\\sqrt{3}\\, Z} \\quad \\text{(triphase\u0301, } V \\text{ compose\u0301e)} \\qquad I_{sc} = \\frac{V}{Z} \\quad \\text{(monophase\u0301, } V \\text{ simple)} \\]<\/div>\r\n\t<\/figure>\r\n\t<\/p>\n<p><strong>Ou\u0300&nbsp;:<\/strong><\/p>\n<ul>\n<li>\\(I_{sc}\\) \u2014 courant de court-circuit pre\u0301sume\u0301 (A)<\/li>\n<li>\\(V\\) \u2014 tension d'alimentation au point de de\u0301faut (V)&nbsp;: tension compose\u0301e pour les re\u0301seaux triphase\u0301s, tension simple pour les re\u0301seaux monophase\u0301s<\/li>\n<li>\\(Z\\) \u2014 impe\u0301dance e\u0301quivalente totale entre la source et le point de de\u0301faut (\u03a9), incluant la source, les transformateurs et les ca\u0302bles<\/li>\n<li>\\(\\sqrt{3} \\approx 1.732\\) \u2014 facteur reliant les grandeurs compose\u0301es et les grandeurs simples dans un syste\u0300me triphase\u0301 e\u0301quilibre\u0301<\/li>\n<\/ul>\n<p>La formule donne le courant de de\u0301faut efficace syme\u0301trique qui circulerait dans un court-circuit franc (d'impe\u0301dance nulle), a\u0300 partir de l'impe\u0301dance totale de tout ce qui se trouve en amont du point de de\u0301faut.<\/p>\n<p>\r\n<\/section>\n<style id=\"wpcoderpro-inline-2\">.calculation-box {\r\n\tborder-bottom: none !important;\r\n}<\/style><section id=\"calculation\" class=\"calculation-box\" aria-labelledby=\"calculation-title\">\r\n\t<div id=\"calculation-title\" class=\"not-prose font-display\"><span class=\"icon icon-unordered-list\" aria-hidden=\"true\"><\/span><h2>Courant de court-circuit \u2013 Exemple de calcul<\/h2><\/div>\r\n\r\n<\/p>\n<p><strong>Exemple&nbsp;:<\/strong> une alimentation triphase\u0301e de 400 V alimente un tableau de distribution par l'interme\u0301diaire de ca\u0302bles et d'un transformateur dont l'impe\u0301dance e\u0301quivalente totale est de 50 m\u03a9 (0,05 \u03a9). Quel courant de de\u0301faut un court-circuit franc au niveau du tableau produirait-il&nbsp;?<\/p>\n<p>\\[ I_{sc} = \\frac{V}{\\sqrt{3}\\, Z} = \\frac{400}{1.732 \\times 0.05} \\]<\/p>\n<p>\\[ I_{sc} = \\frac{400}{0.0866} \\approx 4618.8 \\text{ A} \\]<\/p>\n<p><strong>Re\u0301sultat&nbsp;:<\/strong> \\(I_{sc} \\approx 4.62\\) kA. Tout disjoncteur ou fusible installe\u0301 a\u0300 cet endroit doit posse\u0301der un pouvoir de coupure supe\u0301rieur a\u0300 cette valeur.<\/p>\n<p>\n\r\n<\/section>\n<h2>Comment utiliser le calculateur<\/h2>\n<ol>\n<li>Se\u0301lectionnez le type de <strong>re\u0301seau<\/strong>&nbsp;: <em>Triphase\u0301 (V compose\u0301e)<\/em> ou <em>Monophase\u0301 (V simple)<\/em>. La tension que vous saisissez doit correspondre a\u0300 ce choix.<\/li>\n<li>Saisissez la <strong>tension d'alimentation (V)<\/strong> au point de de\u0301faut et choisissez l'unite\u0301 (V ou kV). Pour un re\u0301seau triphase\u0301 de 400 V, saisissez 400&nbsp;; pour un circuit monophase\u0301 de 230 V, saisissez 230.<\/li>\n<li>Saisissez l'<strong>impe\u0301dance (Z)<\/strong> \u2014 l'impe\u0301dance e\u0301quivalente totale de la source, des transformateurs et des ca\u0302bles jusqu'au point de de\u0301faut \u2014 puis se\u0301lectionnez m\u03a9 ou \u03a9. Les gestionnaires de re\u0301seau communiquent souvent cette valeur&nbsp;; si seule l'impe\u0301dance du transformateur est connue, c'est ge\u0301ne\u0301ralement la part pre\u0301ponde\u0301rante.<\/li>\n<li>Lisez le <strong>courant de court-circuit pre\u0301sume\u0301<\/strong> en ampe\u0300res, avec une valeur lisible en A\/kA\/MA et le de\u0301tail du calcul.<\/li>\n<\/ol>\n<h2>Qu'est-ce que le courant de court-circuit pre\u0301sume\u0301&nbsp;?<\/h2>\n<p>Le courant de court-circuit pre\u0301sume\u0301 (Icc) est le courant qui circulerait en un point donne\u0301 d'un circuit si un de\u0301faut parfait, d'impe\u0301dance nulle, s'y produisait \u2014 un court-circuit franc entre conducteurs ou avec la terre. Il de\u0301pend entie\u0300rement de la tension d'alimentation et de l'impe\u0301dance totale de tout ce qui est situe\u0301 en amont : le re\u0301seau de distribution, le transformateur d'alimentation et les ca\u0302bles entre la source et le point de de\u0301faut. Plus l'impe\u0301dance est faible, plus le courant de de\u0301faut est e\u0301leve\u0301.<\/p>\n<p>Ce chiffre est important pour deux raisons. D'abord, chaque appareil de protection (fusible, disjoncteur, DDR) posse\u0300de un <em>pouvoir de coupure<\/em> nominal \u2014 le courant de de\u0301faut maximal qu'il peut couper sans danger. Si le courant de de\u0301faut pre\u0301sume\u0301 a\u0300 son emplacement de\u0301passe cette valeur, l'appareil risque de se de\u0301truire lors du de\u0301faut au lieu de de\u0301clencher. Ensuite, le courant de de\u0301faut doit e\u0302tre suffisamment e\u0301leve\u0301 pour faire de\u0301clencher la protection rapidement : un ca\u0302ble tre\u0300s long et de faible section ajoute de l'impe\u0301dance, abaisse le courant de de\u0301faut et peut laisser un de\u0301faut en dessous du seuil de de\u0301clenchement. La ve\u0301rification de l'Icc en bout de circuit fait partie inte\u0301grante de la validation d'une installation e\u0301lectrique.<\/p>\n<p>Quelques valeurs typiques donnent un ordre de grandeur&nbsp;: une alimentation domestique monophase\u0301e peut pre\u0301senter un Icc de 1 a\u0300 6 kA au point de livraison, tandis qu'un grand tableau industriel alimente\u0301 par un puissant transformateur peut atteindre 25 kA ou davantage. A\u0300 proximite\u0301 du transformateur, l'impe\u0301dance est plus faible et le courant de de\u0301faut plus e\u0301leve\u0301 ; il de\u0301cro\u00eet a\u0300 mesure que la distance parcourue dans le ca\u0302ble augmente.<\/p>\n<h2>Hypothe\u0300ses et limites<\/h2>\n<ul>\n<li><strong>Valeur efficace syme\u0301trique&nbsp;:<\/strong> le re\u0301sultat est le courant de de\u0301faut alternatif en re\u0301gime e\u0301tabli. Un de\u0301faut re\u0301el comporte aussi une composante continue amortie, si bien que la premie\u0300re cre\u0302te peut atteindre environ 2 a\u0300 2,5 fois cette valeur selon le rapport X\/R. Cela compte pour la ve\u0301rification du pouvoir de fermeture et de l'e\u0301nergie limite\u0301e (I\u00b2t), pas seulement du pouvoir de coupure.<\/li>\n<li><strong>L'impe\u0301dance de source doit e\u0302tre incluse&nbsp;:<\/strong> l'impe\u0301dance saisie doit repre\u0301senter toute la cha\u00eene \u2014 source du gestionnaire, transformateur et ca\u0302bles. Ne retenir que l'impe\u0301dance des ca\u0302bles surestime largement le courant de de\u0301faut, car le transformateur amont est en ge\u0301ne\u0301ral pre\u0301ponde\u0301rant.<\/li>\n<li><strong>Court-circuit franc suppose\u0301&nbsp;:<\/strong> les de\u0301fauts par arc et les de\u0301fauts a\u0300 forte re\u0301sistance tirent moins de courant qu'un court-circuit franc ; cette valeur constitue donc un plafond du pire cas pour l'impe\u0301dance conside\u0301re\u0301e.<\/li>\n<li><strong>Module d'impe\u0301dance utilise\u0301 directement&nbsp;:<\/strong> le calculateur traite Z comme un simple module. Pour un travail pre\u0301cis, calculez Z = \u221a(R\u00b2 + X\u00b2) a\u0300 partir des parties re\u0301sistive et re\u0301active du re\u0301seau amont. Notre calculateur de <a href=\"https:\/\/wpcalc.com\/fr\/ingenierie\/reactance-courant-alternatif\/\">re\u0301actance en courant alternatif<\/a> peut vous aider a\u0300 de\u0301terminer la composante re\u0301active.<\/li>\n<li><strong>Tension nominale suppose\u0301e&nbsp;:<\/strong> en re\u0301alite\u0301, la tension peut le\u0301ge\u0300rement s'effondrer pendant le de\u0301faut, ce qui re\u0301duit le courant re\u0301el de quelques pour cent.<\/li>\n<\/ul>\n<h2>Calculatrices lie\u0301es<\/h2>\n<p>Le calcul de court-circuit est une application directe de la <a href=\"https:\/\/wpcalc.com\/fr\/ingenierie\/loi-d-ohm\/\">loi d'Ohm<\/a> avec l'impe\u0301dance totale du circuit. Pour estimer l'impe\u0301dance ajoute\u0301e par une longueur de ca\u0302ble \u2014 laquelle abaisse le courant de de\u0301faut au bout de la ligne \u2014 utilisez le calculateur de <a href=\"https:\/\/wpcalc.com\/fr\/ingenierie\/chute-de-tension\/\">chute de tension<\/a>. Si vous e\u0301valuez aussi la qualite\u0301 de l'e\u0301nergie de l'installation, le calculateur de <a href=\"https:\/\/wpcalc.com\/fr\/ingenierie\/relevement-facteur-de-puissance\/\">compensation du facteur de puissance<\/a> couvre la partie re\u0301active de la charge.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Estimez le courant de court-circuit pr\u00e9sum\u00e9 (courant de d\u00e9faut) en un point d'une installation \u00e9lectrique. Saisissez la tension d'alimentation, l'imp\u00e9dance totale jusqu'au point de d\u00e9faut et choisissez triphas\u00e9 ou monophas\u00e9.<\/p>\n","protected":false},"author":3168,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[8],"tags":[9],"class_list":["post-5814","post","type-post","status-publish","format-standard","hentry","category-ingenierie","tag-electricite"],"acf":[],"_links":{"self":[{"href":"https:\/\/wpcalc.com\/fr\/wp-json\/wp\/v2\/posts\/5814","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wpcalc.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/wpcalc.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/wpcalc.com\/fr\/wp-json\/wp\/v2\/users\/3168"}],"replies":[{"embeddable":true,"href":"https:\/\/wpcalc.com\/fr\/wp-json\/wp\/v2\/comments?post=5814"}],"version-history":[{"count":1,"href":"https:\/\/wpcalc.com\/fr\/wp-json\/wp\/v2\/posts\/5814\/revisions"}],"predecessor-version":[{"id":6059,"href":"https:\/\/wpcalc.com\/fr\/wp-json\/wp\/v2\/posts\/5814\/revisions\/6059"}],"wp:attachment":[{"href":"https:\/\/wpcalc.com\/fr\/wp-json\/wp\/v2\/media?parent=5814"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/wpcalc.com\/fr\/wp-json\/wp\/v2\/categories?post=5814"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/wpcalc.com\/fr\/wp-json\/wp\/v2\/tags?post=5814"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}